[PATCH 11/18] HID: input: calculate resolution for pressure

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Assume that if the pressure is given in newtons it should be normalized
to grams. If the pressure has no unit do not calculate resolution.

Signed-off-by: Angela Czubak <acz@xxxxxxxxxxxx>
---
 drivers/hid/hid-input.c | 13 +++++++++++++
 1 file changed, 13 insertions(+)

diff --git a/drivers/hid/hid-input.c b/drivers/hid/hid-input.c
index 81eb277dee91..b680641a30c0 100644
--- a/drivers/hid/hid-input.c
+++ b/drivers/hid/hid-input.c
@@ -257,6 +257,19 @@ __s32 hidinput_calc_abs_res(const struct hid_field *field, __u16 code)
 		}
 		break;
 
+	case ABS_PRESSURE:
+	case ABS_MT_PRESSURE:
+		if (field->unit == 0xe111) {		/* If newtons */
+			/* Convert to grams */
+			prev = physical_extents;
+			physical_extents *= 10197;
+			if (physical_extents < prev)
+				return 0;
+			unit_exponent -= 2;
+		} else if (field->unit != 0x101) {	/* If not grams */
+			return 0;
+		}
+		break;
 	default:
 		return 0;
 	}
-- 
2.34.1.307.g9b7440fafd-goog