Hi, On Mon, Apr 12, 2021 at 6:20 PM Johnny Chuang <johnny.chuang.emc@xxxxxxxxx> wrote: > > Fixes: 43b7029f475e ("HID: i2c-hid: Send power-on command after reset"). Note that the "Fixes" tag actually belongs down at the end. It also shouldn't have a "." at the end. Presumably the maintainer can adjust this when landing? > For ELAN touchscreen, we found our boot code of IC was not flexible enough > to receive and handle this command. > Once the FW main code of our controller is crashed for some reason, > the controller could not be enumerated successfully to be recognized > by the system host. therefore, it lost touch functionality. > > Add quirk for skip send power-on command after reset. > It will impact to ELAN touchscreen and touchpad on HID over I2C projects. > > Signed-off-by: Johnny Chuang <johnny.chuang.emc@xxxxxxxxx> This patch looks fine to me, thus: Reviewed-by: Douglas Anderson <dianders@xxxxxxxxxxxx> I can confirm that after applying this patch I can recovery my borked touchscreen (which got borked by a failed firmware update ages ago): Tested-by: Douglas Anderson <dianders@xxxxxxxxxxxx>