On 02/02/2015 09:48 PM, Mika Westerberg wrote: > On Mon, Feb 02, 2015 at 09:19:51PM +0800, Sebastien Bourdeauducq wrote: >> With this computer nothing is normal. Every single component except the CPU, >> display and USB has major issues under Linux. > > We need to get one here then. Can you point me to the exact model? That's a Lenovo Thinkpad Tablet 10, P/N 20C3001VHH. What would be the plan for you to get one? > Since it has 20k internal pull-up configured, I'm guessing something > (the digitizer) drives it low like it still has something to report. Do > you see in the dmesg if the i2c-hid.c is able to read reports from the > device? When I made the interrupt falling edge sensitive, i2c-hid was able to read the first report as I could move the mouse cursor once using the stylus. A possible scenario is: 1) the digitizer is holding the interrupt line low after booting 2) enumerating or otherwise initializing the digitizer causes it to release the interrupt line 3) using the stylus queues several reports in the device and it asserts the interrupt line again. However, with the interrupt configured as edge sensitive, only the first of those reports are retrieved and subsequent ones are lost, with the interrupt line stuck. Maybe the interrupt should be level sensitive and enabled only after certain parts of the device initialization have taken place. Sébastien -- To unsubscribe from this list: send the line "unsubscribe linux-input" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html