On 2/12/25 12:18 PM, Jonathan Santos wrote: > When the device is configured to Sinc5 filter and decimation x8, > output data is reduced to 16-bits in order to support 1 MHz of > sampling frequency due to clock limitation. It would be a bit more clear if this said that x8 is only possible with sinc5, so we don't have to check the filter type in the code. At first, I thought the code was missing that part of the check. > > Use multiple scan types feature to enable the driver to switch > scan type in runtime, making possible to support both 24-bit and > 16-bit resolution. > > Signed-off-by: Jonathan Santos <Jonathan.Santos@xxxxxxxxxx> > --- Reviewed-by: David Lechner <dlechner@xxxxxxxxxxx>