On Thu, 19 Dec 2024 13:25:23 -0600 David Lechner <dlechner@xxxxxxxxxxxx> wrote: > Combine two duplicate sections describing in_currentY_raw. > > This went unnoticed until we renamed in_currentX_raw to in_currentY_raw > and the kernel test robot found the duplication. > > Reported-by: kernel test robot <lkp@xxxxxxxxx> > Closes: https://lore.kernel.org/oe-kbuild-all/202412200256.OB5Hmw5Q-lkp@xxxxxxxxx/ > Signed-off-by: David Lechner <dlechner@xxxxxxxxxxxx> Applied. Thanks, J > --- > Documentation/ABI/testing/sysfs-bus-iio | 19 +++++-------------- > 1 file changed, 5 insertions(+), 14 deletions(-) > > diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio > index d97c35057a034c76ed433e3e6de0aff8ec4bbb70..25d366d452a55293c420300335a0271a28855107 100644 > --- a/Documentation/ABI/testing/sysfs-bus-iio > +++ b/Documentation/ABI/testing/sysfs-bus-iio > @@ -168,18 +168,6 @@ Description: > is required is a consistent labeling. Units after application > of scale and offset are millivolts. > > -What: /sys/bus/iio/devices/iio:deviceX/in_currentY_raw > -What: /sys/bus/iio/devices/iio:deviceX/in_currentY_supply_raw > -KernelVersion: 3.17 > -Contact: linux-iio@xxxxxxxxxxxxxxx > -Description: > - Raw (unscaled no bias removal etc.) current measurement from > - channel Y. In special cases where the channel does not > - correspond to externally available input one of the named > - versions may be used. The number must always be specified and > - unique to allow association with event codes. Units after > - application of scale and offset are milliamps. > - > What: /sys/bus/iio/devices/iio:deviceX/in_powerY_raw > KernelVersion: 4.5 > Contact: linux-iio@xxxxxxxxxxxxxxx > @@ -1700,15 +1688,18 @@ Description: > or without compensation from tilt sensors. > > What: /sys/bus/iio/devices/iio:deviceX/in_currentY_raw > +What: /sys/bus/iio/devices/iio:deviceX/in_currentY_supply_raw > What: /sys/bus/iio/devices/iio:deviceX/in_currentY_i_raw > What: /sys/bus/iio/devices/iio:deviceX/in_currentY_q_raw > -KernelVersion: 3.18 > +KernelVersion: 3.17 > Contact: linux-iio@xxxxxxxxxxxxxxx > Description: > Raw current measurement from channel Y. Units are in milliamps > after application of scale and offset. If no offset or scale is > present, output should be considered as processed with the > - unit in milliamps. > + unit in milliamps. In special cases where the channel does not > + correspond to externally available input one of the named > + versions may be used. > > Channels with 'i' and 'q' modifiers always exist in pairs and both > channels refer to the same signal. The 'i' channel contains the in-phase > > --- > base-commit: fe2a04fbcbfe44694fcb36ff6212fce54b8f56cc > change-id: 20241219-iio-abi-combine-current-input-sections-c62cf5dbfa9b > > Best regards,