On Tue, Dec 03, 2024 at 08:52:37PM +0000, Lothar Rubusch wrote: > Add interrupt-names INT1 and INT2 for the two interrupt lines of the > sensor. Only one line will be connected for incoming events. The driver > needs to be configured accordingly. If no interrupt line is set up, the > sensor will still measure, but no events are possible. > > Signed-off-by: Lothar Rubusch <l.rubusch@xxxxxxxxx> > --- > .../devicetree/bindings/iio/accel/adi,adxl345.yaml | 13 +++++++++++++ > 1 file changed, 13 insertions(+) > > diff --git a/Documentation/devicetree/bindings/iio/accel/adi,adxl345.yaml b/Documentation/devicetree/bindings/iio/accel/adi,adxl345.yaml > index 280ed479ef5..c3483a4b652 100644 > --- a/Documentation/devicetree/bindings/iio/accel/adi,adxl345.yaml > +++ b/Documentation/devicetree/bindings/iio/accel/adi,adxl345.yaml > @@ -37,6 +37,17 @@ properties: > interrupts: > maxItems: 1 > > + interrupt-names: > + Data ready is only available on INT1, but events can use either or > + both pins. If not specified, first element assumed to correspond > + to INT1 and second (where present) to INT2. > + minItems: 1 > + maxItems: 2 This does not match your interrupts property. > + items: > + enum: > + - INT1 > + - INT2 Best regards, Krzysztof