[PATCH v3 03/10] iio: accel: adxl345: measure right-justified

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Make measurements right-justified, since it is the default for the
driver and sensor. By not setting the ADXL345_DATA_FORMAT_JUSTIFY bit,
the data becomes right-judstified. This was the original setting, there
is no reason to change it to left-justified, where right-justified
simplifies working on the registers.

Signed-off-by: Lothar Rubusch <l.rubusch@xxxxxxxxx>
---
 drivers/iio/accel/adxl345_core.c | 1 -
 1 file changed, 1 deletion(-)

diff --git a/drivers/iio/accel/adxl345_core.c b/drivers/iio/accel/adxl345_core.c
index 0b613f5652e..11eb0ceef39 100644
--- a/drivers/iio/accel/adxl345_core.c
+++ b/drivers/iio/accel/adxl345_core.c
@@ -184,7 +184,6 @@ int adxl345_core_probe(struct device *dev, struct regmap *regmap,
 	struct iio_dev *indio_dev;
 	u32 regval;
 	unsigned int data_format_mask = (ADXL345_DATA_FORMAT_RANGE |
-					 ADXL345_DATA_FORMAT_JUSTIFY |
 					 ADXL345_DATA_FORMAT_FULL_RES |
 					 ADXL345_DATA_FORMAT_SELF_TEST);
 	int ret;
-- 
2.39.5