The adxl345 sensor uses one of two interrupt lines, INT1 or INT2. The interrupt lines are used to signal feature events such as watermark reached, single tap, double tap, activity, etc. Only one interrupt line is used and must be configured. The adxl345 default is to use INT1 and in many installations only INT1 is even connected. Therefore configure INT1 as the sensor's default interrupt line. Signed-off-by: Lothar Rubusch <l.rubusch@xxxxxxxxx> --- drivers/iio/accel/adxl345_core.c | 2 ++ 1 file changed, 2 insertions(+) diff --git a/drivers/iio/accel/adxl345_core.c b/drivers/iio/accel/adxl345_core.c index c8d9e1f9e0..32163cfe6f 100644 --- a/drivers/iio/accel/adxl345_core.c +++ b/drivers/iio/accel/adxl345_core.c @@ -131,6 +131,7 @@ struct adxl34x_state { const struct adxl345_chip_info *info; struct regmap *regmap; bool fifo_delay; /* delay: delay is needed for SPI */ + u8 intio; }; #define ADXL345_CHANNEL(index, axis) { \ @@ -345,6 +346,7 @@ int adxl345_core_probe(struct device *dev, struct regmap *regmap, return -ENODEV; st->fifo_delay = fifo_delay_default; + st->intio = ADXL345_INT1; indio_dev->name = st->info->name; indio_dev->info = &adxl345_info; -- 2.39.5