Re: [PATCH v1 13/13] iio: chemical: bme680: Add support for preheat current

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Thu, Oct 10, 2024 at 11:00:30PM +0200, vamoirid wrote:
> From: Vasileios Amoiridis <vassilisamir@xxxxxxxxx>
> 
> Add functionality to inject a specified amount of current to the heating
> plate before the start of the gas measurement to allow the sensor to reach
> faster to the requested temperature.

...

> +	data->preheat_curr = 0; /* milliamps */

Instead of the comment, make it better to any appearance of the variable in the
code by adding unit suffix.

	data->preheat_curr_mA = 0;

(yes, capital 'A').

-- 
With Best Regards,
Andy Shevchenko