On 13/09/2024 12:00, Jianping.Shen@xxxxxxxxxxxx wrote: > From: Shen Jianping <Jianping.Shen@xxxxxxxxxxxx> > > Add the iio driver for bosch imu smi240. The smi240 is a combined > three axis angular rate and three axis acceleration sensor module > with a measurement range of +/-300°/s and up to 16g. This driver > provides raw data access for each axis through sysfs, and tiggered > buffer for continuous sampling. A synchronous acc and gyro sampling > can be triggered by setting the capture bit in spi read command. > > dt-bindings: > v1 -> v2 > - Add more detail in description > - Add maintainer > - Add vdd and vddio power supply > - Use generic node name > - Order the properties according to DTS coding style > > v2 -> v3 > - Improve description > - Improve supply definition > - Make supply definition as required > - Add supply definition in example > > v3 -> v4 > - No changes > > v4 -> v5 > - No changes > > v5 -> v6 > - Fix checkpatch findings > > v6 -> v7 > - No changes > > imu driver: > v1 -> v2 > - Use regmap for register access > - Redefine channel for each singel axis > - Provide triggered buffer > - Fix findings in Kconfig > - Remove unimportant functions > > v2 -> v3 > - Use enum für capture mode > - Using spi default init value instead manual init > - remove duplicated module declaration > - Fix code to avoid warning > > v3 -> v4 > - Use DMA safe buffer > - Use channel info instead of custom ABI > - Fix other findings > > v4 -> v5 > - Merge the implementation in one simple file > - Add channel info for acc/gyro data channel > - Fix other findings ? > > v5 -> v6 > - Fix checkpatch findings > - Fix review findings ? What exactly happened? Your changelog is way too vague. What happened with our reviews? Why did you get multiple of them? Best regards, Krzysztof