[PATCH v1 04/10] iio: pressure: bmp280: Use bulk read for humidity calibration data

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Convert individual reads to a bulk read for the humidity calibration data.

Signed-off-by: Vasileios Amoiridis <vassilisamir@xxxxxxxxx>
---
 drivers/iio/pressure/bmp280-core.c | 57 +++++++++---------------------
 drivers/iio/pressure/bmp280.h      |  5 +++
 2 files changed, 21 insertions(+), 41 deletions(-)

diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c
index 3deaa57bb3f5..9c32266403bd 100644
--- a/drivers/iio/pressure/bmp280-core.c
+++ b/drivers/iio/pressure/bmp280-core.c
@@ -118,6 +118,8 @@ enum bmp580_odr {
  */
 enum { T1, T2, T3, P1, P2, P3, P4, P5, P6, P7, P8, P9 };
 
+enum { H2 = 0, H3 = 2, H4 = 3, H5 = 4, H6 = 6 };
+
 enum {
 	/* Temperature calib indexes */
 	BMP380_T1 = 0,
@@ -344,6 +346,7 @@ static int bme280_read_calib(struct bmp280_data *data)
 {
 	struct bmp280_calib *calib = &data->calib.bmp280;
 	struct device *dev = data->dev;
+	s16 h4_upper, h4_lower;
 	unsigned int tmp;
 	int ret;
 
@@ -352,14 +355,6 @@ static int bme280_read_calib(struct bmp280_data *data)
 	if (ret)
 		return ret;
 
-	/*
-	 * Read humidity calibration values.
-	 * Due to some odd register addressing we cannot just
-	 * do a big bulk read. Instead, we have to read each Hx
-	 * value separately and sometimes do some bit shifting...
-	 * Humidity data is only available on BME280.
-	 */
-
 	ret = regmap_read(data->regmap, BME280_REG_COMP_H1, &tmp);
 	if (ret) {
 		dev_err(dev, "failed to read H1 comp value\n");
@@ -368,43 +363,23 @@ static int bme280_read_calib(struct bmp280_data *data)
 	calib->H1 = tmp;
 
 	ret = regmap_bulk_read(data->regmap, BME280_REG_COMP_H2,
-			       &data->le16, sizeof(data->le16));
-	if (ret) {
-		dev_err(dev, "failed to read H2 comp value\n");
-		return ret;
-	}
-	calib->H2 = sign_extend32(le16_to_cpu(data->le16), 15);
-
-	ret = regmap_read(data->regmap, BME280_REG_COMP_H3, &tmp);
-	if (ret) {
-		dev_err(dev, "failed to read H3 comp value\n");
-		return ret;
-	}
-	calib->H3 = tmp;
-
-	ret = regmap_bulk_read(data->regmap, BME280_REG_COMP_H4,
-			       &data->be16, sizeof(data->be16));
-	if (ret) {
-		dev_err(dev, "failed to read H4 comp value\n");
-		return ret;
-	}
-	calib->H4 = sign_extend32(((be16_to_cpu(data->be16) >> 4) & 0xff0) |
-				  (be16_to_cpu(data->be16) & 0xf), 11);
-
-	ret = regmap_bulk_read(data->regmap, BME280_REG_COMP_H5,
-			       &data->le16, sizeof(data->le16));
+			       data->bme280_humid_cal_buf,
+			       sizeof(data->bme280_humid_cal_buf));
 	if (ret) {
-		dev_err(dev, "failed to read H5 comp value\n");
+		dev_err(dev, "failed to read humidity calibration values\n");
 		return ret;
 	}
-	calib->H5 = sign_extend32(FIELD_GET(BME280_COMP_H5_MASK, le16_to_cpu(data->le16)), 11);
 
-	ret = regmap_read(data->regmap, BME280_REG_COMP_H6, &tmp);
-	if (ret) {
-		dev_err(dev, "failed to read H6 comp value\n");
-		return ret;
-	}
-	calib->H6 = sign_extend32(tmp, 7);
+	calib->H2 = get_unaligned_le16(&data->bme280_humid_cal_buf[H2]);
+	calib->H3 = data->bme280_humid_cal_buf[H3];
+	h4_upper = FIELD_GET(BME280_COMP_H4_MASK_UP,
+			     get_unaligned_be16(&data->bme280_humid_cal_buf[H4]));
+	h4_lower = FIELD_GET(BME280_COMP_H4_MASK_LOW,
+			     get_unaligned_be16(&data->bme280_humid_cal_buf[H4]));
+	calib->H4 = sign_extend32((h4_upper & ~BME280_COMP_H4_MASK_LOW) | h4_lower, 11);
+	calib->H5 = sign_extend32(FIELD_GET(BME280_COMP_H5_MASK,
+				  get_unaligned_le16(&data->bme280_humid_cal_buf[H5])), 11);
+	calib->H6 = data->bme280_humid_cal_buf[H6];
 
 	return 0;
 }
diff --git a/drivers/iio/pressure/bmp280.h b/drivers/iio/pressure/bmp280.h
index ccacc67c1473..56c01f224728 100644
--- a/drivers/iio/pressure/bmp280.h
+++ b/drivers/iio/pressure/bmp280.h
@@ -257,8 +257,12 @@
 #define BME280_REG_COMP_H5		0xE5
 #define BME280_REG_COMP_H6		0xE7
 
+#define BME280_COMP_H4_MASK_UP		GENMASK(15, 4)
+#define BME280_COMP_H4_MASK_LOW		GENMASK(3, 0)
 #define BME280_COMP_H5_MASK		GENMASK(15, 4)
 
+#define BME280_CONTIGUOUS_CALIB_REGS	7
+
 #define BME280_OSRS_HUMIDITY_MASK	GENMASK(2, 0)
 #define BME280_OSRS_HUMIDITY_SKIP	0
 #define BME280_OSRS_HUMIDITY_1X		1
@@ -423,6 +427,7 @@ struct bmp280_data {
 		/* Calibration data buffers */
 		__le16 bmp280_cal_buf[BMP280_CONTIGUOUS_CALIB_REGS / 2];
 		__be16 bmp180_cal_buf[BMP180_REG_CALIB_COUNT / 2];
+		u8 bme280_humid_cal_buf[BME280_CONTIGUOUS_CALIB_REGS];
 		u8 bmp380_cal_buf[BMP380_CALIB_REG_COUNT];
 		/* Miscellaneous, endianness-aware data buffers */
 		__le16 le16;
-- 
2.25.1





[Index of Archives]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Input]     [Linux Kernel]     [Linux SCSI]     [X.org]