[PATCH] iio: light: apds9306: Fix error handing

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



The return value of 'iio_gts_find_int_time_by_sel()' is assigned to
variable 'intg_old' but value of 'ret' is checked for error. Update to
use 'intg_old' for error checking.

Fixes: 620d1e6c7a3f ("iio: light: Add support for APDS9306 Light Sensor")
Signed-off-by: Mudit Sharma <muditsharma.info@xxxxxxxxx>
---
 drivers/iio/light/apds9306.c | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/iio/light/apds9306.c b/drivers/iio/light/apds9306.c
index d6627b3e6000..66a063ea3db4 100644
--- a/drivers/iio/light/apds9306.c
+++ b/drivers/iio/light/apds9306.c
@@ -583,8 +583,8 @@ static int apds9306_intg_time_set(struct apds9306_data *data, int val2)
 		return ret;
 
 	intg_old = iio_gts_find_int_time_by_sel(&data->gts, intg_time_idx);
-	if (ret < 0)
-		return ret;
+	if (intg_old < 0)
+		return intg_old;
 
 	if (intg_old == val2)
 		return 0;
-- 