On Tue, Jun 25, 2024 at 12:45 PM Ceclan, Dumitru <mitrutzceclan@xxxxxxxxx> wrote: > > On 21/06/2024 16:26, Alexandru Ardelean wrote: > > On Fri, Jun 21, 2024 at 3:05 PM Dumitru Ceclan <mitrutzceclan@xxxxxxxxx> wrote: > >> > >> The ADC ad7192 is a sigma delta ADC with a sequencer that does not > >> require a disable_one callback as all enable channel bits are within > >> the same register. > >> > >> Remove the requirement of the disable_one callback for sigma delta ADCs > >> with a sequencer. > >> > >> This patch could be squashed with the commit that it fixes from patch > >> series: Add support for AD411x > >> > > > > This fix looks fine. > > But, then this raises a question if this needs be to extended to the > > `disable_all` and maybe `indio_dev->info->update_scan_mode` check. > > And if so, how should this be handled? > > > > For example: > > drivers/iio/adc/ad7124.c: .disable_all = ad7124_disable_all, > > drivers/iio/adc/ad7173.c: .disable_all = ad7173_disable_all, > > drivers/iio/adc/ad7192.c: .disable_all = ad7192_disable_all, > > drivers/iio/adc/ad7192.c: .disable_all = ad7192_disable_all, > > > > And: > > drivers/iio/adc/ad7124.c: ret = ad_sd_init(&st->sd, indio_dev, spi, > > &ad7124_sigma_delta_info); > > drivers/iio/adc/ad7173.c: ret = ad_sd_init(&st->sd, indio_dev, spi, > > &ad7173_sigma_delta_info); > > drivers/iio/adc/ad7192.c: ret = ad_sd_init(&st->sd, indio_dev, spi, > > st->chip_info->sigma_delta_info); > > drivers/iio/adc/ad7780.c: ad_sd_init(&st->sd, indio_dev, spi, > > &ad7780_sigma_delta_info); > > drivers/iio/adc/ad7791.c: ad_sd_init(&st->sd, indio_dev, spi, > > &ad7791_sigma_delta_info); > > drivers/iio/adc/ad7793.c: ad_sd_init(&st->sd, indio_dev, spi, > > &ad7793_sigma_delta_info); > > > > At least the ad7791.c & ad7793.c drivers support parts with more than > > 1 channel, and there does not seem to be any `disable_all` hook > > defined (at least in iio/testing). > > I have not gone too deep with `indio_dev->info->update_scan_mode`, but > > it would be worth to do a check there as well > > > > > > disable_all and update_scan_mode callbacks are required only when the ADC > features a sequencer, as in you can enable more than one channel at a time > and the ADC will automatically cycle conversions through all enabled channels. > > This feature is signaled by setting the ad_sigma_delta_info.num_slots attribute > to a value >1. The only drivers that set .num_slot from what I see are: > ad7173, ad7192, ad7124. So only these 3 are relevant in this discussion. > > For ad7192, disable_all() is useless as both ad7192_set_channel() and > ad7192_update_scan_mode() actually set to 0 other channel enable bits. > > I do not see any reason at this moment to extend this to disable_all and > update_scan_mode. Ack. Thanks for the explanation :) I think I also misread the code there; I was thinking num_slots is related to the number of channels. > > >> Fixes: a25a0aab2187 ("iio: adc: ad_sigma_delta: add disable_one callback") > >> Signed-off-by: Dumitru Ceclan <dumitru.ceclan@xxxxxxxxxx> > >> --- > >> drivers/iio/adc/ad_sigma_delta.c | 5 ----- > >> 1 file changed, 5 deletions(-) > >> > >> diff --git a/drivers/iio/adc/ad_sigma_delta.c b/drivers/iio/adc/ad_sigma_delta.c > >> index d6b5fca034a0..8c062b0d26e3 100644 > >> --- a/drivers/iio/adc/ad_sigma_delta.c > >> +++ b/drivers/iio/adc/ad_sigma_delta.c > >> @@ -672,11 +672,6 @@ int ad_sd_init(struct ad_sigma_delta *sigma_delta, struct iio_dev *indio_dev, > >> dev_err(&spi->dev, "ad_sigma_delta_info lacks disable_all().\n"); > >> return -EINVAL; > >> } > >> - > >> - if (!info->disable_one) { > >> - dev_err(&spi->dev, "ad_sigma_delta_info lacks disable_one().\n"); > >> - return -EINVAL; > >> - } > >> } > >> > >> if (info->irq_line) > >> -- > >> 2.43.0 > >> > >> >