On Tue, 18 Jun 2024, at 10:05 AM, Chris Morgan wrote: > From: Chris Morgan <macromorgan@xxxxxxxxxxx> Thanks Chris! > Add support for the AXP717 PMIC battery charger. The AXP717 differs > greatly from existing AXP battery chargers in that it cannot measure > the discharge current. The battery does seem to report a discharge current with no USB power connected, do you think this is not accurate? localhost:/sys/class/power_supply/axp20x-battery# cat current_now 433000 Otherwise Working charge state, percentage and current/voltage. Thanks! Tested-by: Ryan Walklin <ryan@xxxxxxxxxxxxx> Regards, Ryan