On Tue, Jun 18, 2024 at 05:21:34PM +0300, Alisa-Dariana Roman wrote: > There are actually 4 configuration modes of clock source for AD719X > devices. Either a crystal can be attached externally between MCLK1 and > MCLK2 pins, or an external CMOS-compatible clock can drive the MCLK2 > pin. The other 2 modes make use of the 4.92MHz internal clock. > > To configure external clock as either a crystal or a CMOS-compatible > clock, changing the register settings is necessary. Therefore, add clock > name xtal alongside mclk. By selecting one or the other, the register is > configured. > > The presence of an external clock source is optional, not required. When > absent, internal clock is used. Modify required property accordingly. Reviewed-by: Conor Dooley <conor.dooley@xxxxxxxxxxxxx>
Attachment:
signature.asc