Add new compatible ti,am62-eqep for TI K3 devices. If a device uses this compatible, require power-domains property. Since there is only one functional and interface clock for eqep, clock-names is not really required, so removed from required section, make it optional for ti,am3352-eqep compatible, and update the example. The clock-name also changed for TI K3 SoCs so do not allow clock-names property for the new compatible. While we are here, add an example using ti,am62-eqep compatible. Signed-off-by: Judith Mendez <jm@xxxxxx> Acked-by: Conor Dooley <conor.dooley@xxxxxxxxxxxxx> Reviewed-by: David Lechner <david@xxxxxxxxxxxxxx> --- Changes since v3: - No change --- .../devicetree/bindings/counter/ti-eqep.yaml | 44 ++++++++++++++++--- 1 file changed, 39 insertions(+), 5 deletions(-) diff --git a/Documentation/devicetree/bindings/counter/ti-eqep.yaml b/Documentation/devicetree/bindings/counter/ti-eqep.yaml index 85f1ff83afe72..54611e06064a2 100644 --- a/Documentation/devicetree/bindings/counter/ti-eqep.yaml +++ b/Documentation/devicetree/bindings/counter/ti-eqep.yaml @@ -11,7 +11,9 @@ maintainers: properties: compatible: - const: ti,am3352-eqep + enum: + - ti,am3352-eqep + - ti,am62-eqep reg: maxItems: 1 @@ -21,19 +23,35 @@ properties: maxItems: 1 clocks: - description: The clock that determines the SYSCLKOUT rate for the eQEP - peripheral. + description: The functional and interface clock that determines the clock + rate for the eQEP peripheral. maxItems: 1 clock-names: const: sysclkout + power-domains: + maxItems: 1 + +allOf: + - if: + properties: + compatible: + contains: + enum: + - ti,am62-eqep + then: + properties: + clock-names: false + + required: + - power-domains + required: - compatible - reg - interrupts - clocks - - clock-names additionalProperties: false @@ -43,8 +61,24 @@ examples: compatible = "ti,am3352-eqep"; reg = <0x180 0x80>; clocks = <&l4ls_gclk>; - clock-names = "sysclkout"; interrupts = <79>; }; + - | + #include <dt-bindings/interrupt-controller/irq.h> + #include <dt-bindings/interrupt-controller/arm-gic.h> + #include <dt-bindings/soc/ti,sci_pm_domain.h> + + bus { + #address-cells = <2>; + #size-cells = <2>; + eqep1: counter@23210000 { + compatible = "ti,am62-eqep"; + reg = <0x00 0x23210000 0x00 0x100>; + power-domains = <&k3_pds 60 TI_SCI_PD_EXCLUSIVE>; + clocks = <&k3_clks 60 0>; + interrupts = <GIC_SPI 117 IRQ_TYPE_EDGE_RISING>; + status = "disabled"; + }; + }; ... -- 2.45.1