Re: [PATCH v6 3/9] iio: adc: ad_sigma_delta: add disable_one callback

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Thu, 2024-06-06 at 19:07 +0300, Dumitru Ceclan via B4 Relay wrote:
> From: Dumitru Ceclan <dumitru.ceclan@xxxxxxxxxx>
> 
> Sigma delta ADCs with a sequencer need to disable the previously enabled
> channel when reading using ad_sigma_delta_single_conversion(). This was
> done manually in drivers for devices with sequencers.
> 
> This patch implements handling of single channel disabling after a
> single conversion.
> 
> Signed-off-by: Dumitru Ceclan <dumitru.ceclan@xxxxxxxxxx>
> ---

You could have this done in separate patches... Oh well, this is simple enough
that I don't care much.

Reviewed-by: Nuno Sa <nuno.sa@xxxxxxxxxx>