Hi David,
On 5/25/24 12:49 PM, David Lechner wrote:
On 5/24/24 4:44 PM, Judith Mendez wrote:
On 5/24/24 3:57 PM, David Lechner wrote:
On 5/24/24 3:50 PM, David Lechner wrote:
On 5/23/24 6:15 PM, Judith Mendez wrote:
Add new compatible ti,am62-eqep for TI K3 devices. If a device
uses this compatible, require power-domains property.
Since there is only one functional and interface clock for eqep,
clock-names is not really required. The clock-name also changed
for TI K3 SoCs so make clock-names optional for the new compatible
since there is only one clock that is routed to the IP.
While we are here, add an example using ti,am62-eqep compatible.
Signed-off-by: Judith Mendez <jm@xxxxxx>
---
Changes since v1:
- Fix eqep binding for new compatible, require
power-domains for new compatible
---
.../devicetree/bindings/counter/ti-eqep.yaml | 53 +++++++++++++++++--
1 file changed, 48 insertions(+), 5 deletions(-)
diff --git a/Documentation/devicetree/bindings/counter/ti-eqep.yaml b/Documentation/devicetree/bindings/counter/ti-eqep.yaml
index 85f1ff83afe72..c4bb0231f166a 100644
--- a/Documentation/devicetree/bindings/counter/ti-eqep.yaml
+++ b/Documentation/devicetree/bindings/counter/ti-eqep.yaml
@@ -11,7 +11,9 @@ maintainers:
properties:
compatible:
- const: ti,am3352-eqep
+ enum:
+ - ti,am3352-eqep
+ - ti,am62-eqep
reg:
maxItems: 1
@@ -21,19 +23,43 @@ properties:
maxItems: 1
clocks:
- description: The clock that determines the SYSCLKOUT rate for the eQEP
- peripheral.
+ description: The functional and interface clock that determines the clock
+ rate for the eQEP peripheral.
maxItems: 1
clock-names:
- const: sysclkout
+ enum:
+ - sysclkout
+ - fck
+
If we are making this optional for ti,am62-eqep, why add a new name?
Also, we could change the description to say that sysclockout is not a
great name but is required for backwards compatibility.
+ power-domains:
+ maxItems: 1
+
+allOf:
+ - if:
+ properties:
+ compatible:
+ contains:
+ enum:
+ - ti,am3352-eqep
+ then:
+ required:
+ - clock-names
I just looked at the Linux driver for this and the clock name is
not used in the driver. So we could probably just deprecate the
clock-names property here and not make it required for
ti,am3352-eqep (and not allowed for any new compatibles as
suggested below).
We could do this, although I was under the impression that we should
not drop DT properties just because the linux driver isn't using it,
that is why I went with keeping clock-names around for am335x compatible
and making it optional for am62x compatible.
But if it is all the same, we could drop the the DT property.
~ Judith
I wasn't suggesting to remove clock-names from the bindings, just
deprecate that property in this binding and not use it with any
new compatibles.
In the AM62x technical reference manual, it looks like it calls
the functional and interface clock FICLK rather than FCK. So
I'm just suggesting maybe it just easier to not give it a name
rather than try to get the right name? No name will work with
any future SoCs as well. :-)
Understood, so I will make clock-names optional for ti,am3352-eqep
compatible and not allowed for ti,am62-eqep compatible.
Thanks for your feedback (:
~ Judith