[PATCH] iio: pressure: bmp280: Fix BMP580 temperature reading

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Fix overflow issue when storing BMP580 temperature reading and
properly preserve sign of 24-bit data.

Signed-off-by: Adam Rizkalla <ajarizzo@xxxxxxxxx>
---
 drivers/iio/pressure/bmp280-core.c | 10 +++++-----
 1 file changed, 5 insertions(+), 5 deletions(-)

diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c
index fe8734468ed3..e79c9715bb28 100644
--- a/drivers/iio/pressure/bmp280-core.c
+++ b/drivers/iio/pressure/bmp280-core.c
@@ -1393,12 +1393,12 @@ static int bmp580_read_temp(struct bmp280_data *data, int *val, int *val2)
 
 	/*
 	 * Temperature is returned in Celsius degrees in fractional
-	 * form down 2^16. We rescale by x1000 to return milli Celsius
-	 * to respect IIO ABI.
+	 * form down 2^16. We rescale by x1000 to return millidegrees
+	 * Celsius to respect IIO ABI.
 	 */
-	*val = raw_temp * 1000;
-	*val2 = 16;
-	return IIO_VAL_FRACTIONAL_LOG2;
+	raw_temp = sign_extend32(raw_temp, 23);
+	*val = ((s64)raw_temp * 1000) / (1 << 16);
+	return IIO_VAL_INT;
 }
 
 static int bmp580_read_press(struct bmp280_data *data, int *val, int *val2)
-- 
2.40.1