Re: [PATCH v3 6/6] iio: pressure: Add triggered buffer support for BMP280 driver

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Wed, Mar 20, 2024 at 06:46:02PM +0100, Vasileios Amoiridis wrote:
> On Wed, Mar 20, 2024 at 01:16:03PM +0200, Andy Shevchenko wrote:
> > On Tue, Mar 19, 2024 at 01:29:25AM +0100, Vasileios Amoiridis wrote:

...

> > >  	/*
> > > -	 * Maximum number of consecutive bytes read for a temperature or
> > > -	 * pressure measurement is 3.
> > > +	 * Maximum number of a burst read for temperature, pressure, humidity
> > > +	 * is 8 bytes.
> > >  	 */
> > > -	if (val_size > 3)
> > > +	if (val_size > 8)
> > 
> > sizeof() / new definition for the buf[] size?
> 
> In a previous commit that I was fixing this SPI driver, Jonathan had mentioned
> that there is no need for a specific definition since it will only be used
> here so that's why I kept it as is.

It seems not only here, but also in the buf[] definition in the struct.

-- 
With Best Regards,
Andy Shevchenko