Document calibration properties and how to set them. Signed-off-by: Andrej Picej <andrej.picej@xxxxxxxxx> --- .../bindings/iio/adc/nxp,imx93-adc.yaml | 15 +++++++++++++++ 1 file changed, 15 insertions(+) diff --git a/Documentation/devicetree/bindings/iio/adc/nxp,imx93-adc.yaml b/Documentation/devicetree/bindings/iio/adc/nxp,imx93-adc.yaml index dacc526dc695..64958be62a6a 100644 --- a/Documentation/devicetree/bindings/iio/adc/nxp,imx93-adc.yaml +++ b/Documentation/devicetree/bindings/iio/adc/nxp,imx93-adc.yaml @@ -46,6 +46,21 @@ properties: "#io-channel-cells": const: 1 + nxp,calib-avg-en: + description: + Enable or disable averaging of calibration time. + enum: [ 0, 1 ] + + nxp,calib-nr-samples: + description: + Selects the number of averaging samples to be used during calibration. + enum: [ 16, 32, 128, 512 ] + + nxp,calib-t-samples: + description: + Specifies the sample time of calibration conversions. + enum: [ 8, 16, 22, 32 ] + required: - compatible - reg -- 2.25.1