On Wed, Mar 13, 2024 at 06:40:06PM +0100, Vasileios Amoiridis wrote: > The scan mask for the BME280 supports humidity measurement needs > to be distinguished from the rest in order for the timestamp to > be able to work. Scan masks are added for different combinations > of measurements. The temperature measurement is always needed for > pressure and humidity measurements. (Just to make sure if you used --histogram diff algo when preparing the series) ... > { > - .type = IIO_HUMIDITYRELATIVE, > + .type = IIO_PRESSURE, > .info_mask_separate = BIT(IIO_CHAN_INFO_PROCESSED) | > BIT(IIO_CHAN_INFO_RAW) | > BIT(IIO_CHAN_INFO_SCALE) | > BIT(IIO_CHAN_INFO_OVERSAMPLING_RATIO), > - .info_mask_shared_by_all = BIT(IIO_CHAN_INFO_SAMP_FREQ) | > + .info_mask_shared_by_all = BIT(IIO_CHAN_INFO_SAMP_FREQ) | Stray change > BIT(IIO_CHAN_INFO_LOW_PASS_FILTER_3DB_FREQUENCY), > + .scan_index = 1, > + .scan_type = { > + .sign = 'u', > + .realbits = 32, > + .storagebits = 32, > + .endianness = IIO_CPU, > + }, > }, -- With Best Regards, Andy Shevchenko