Am Sat, Feb 03, 2024 at 11:06:02AM +0100 schrieb Javier Carrasco: > On 03.02.24 10:58, Christophe JAILLET wrote: > > Le 03/02/2024 à 10:05, Dimitri Fedrau a écrit : > >> [...] > >> drivers/iio/humidity/hdc3020.c | 339 +++++++++++++++++++++++++++++++++ > >> 1 file changed, 339 insertions(+) > > ... > > >> + guard(mutex)(&data->lock); > >> + switch (chan->type) { > >> + case IIO_TEMP: > >> + /* > >> + * Store truncated temperature threshold into 9 LSBs while > >> + * keeping the old humidity threshold in the 7 MSBs. > >> + */ > >> + val = (((val + 45) * 65535 / 175) >> HDC3020_THRESH_TEMP_SHIFT); > > > > Why 175? > > If the span is -40/+120, I guess it should be 160 and if it is -45/+120, > > 165. No? > > > > Maybe something like: > > #define MIN_TEMP -45 (or -40) > > #define MAX_TEMP 120 > > in order to avoid hard coded constant? > > > > the 45 and 175 values come from the conversion formula provided in the > datasheet (page 13), even though the sensor range is from –40°C to 125°C. > Will add following constants: #define MIN_TEMP -40 #define MAX_TEMP 125 It's the supported temperature range by the chip as Javier already explained. Thanks for finding this. > >> [...] Best regards, Dimitri