On 30/01/2024 12:18, Naresh Solanki wrote: > voltage-divider is always an iio consumer at the same time it is > optionally an iio provider. > Hence add #io-channel-cells > Also update example. > output-ohms: > description: > Resistance Rout over which the output voltage is measured. See full-ohms. > @@ -75,12 +82,17 @@ examples: > spi-max-frequency = <1000000>; > }; > }; > - sysv { > + p12v_vd: sysv { > compatible = "voltage-divider"; > io-channels = <&maxadc 1>; > + #io-channel-cells = <1>; > > /* Scale the system voltage by 22/222 to fit the ADC range. */ > output-ohms = <22>; > full-ohms = <222>; /* 200 + 22 */ > }; > + iio-hwmon { > + compatible = "iio-hwmon"; > + io-channels = <&p12v_vd 0>; Why do you add unrelated example? Best regards, Krzysztof