This driver supports 32*3 combinations of fixed ranges and transfer functions, plus custom ranges. So statistically a user has more than 99% chance that the provided default configuration will generate invalid pressure readings if the bindings are not initialized and the driver is instantiated via sysfs. The current patch removes this loophole making sure the driver loads only if the dt has been initialized. Signed-off-by: Petre Rodan <petre.rodan@xxxxxxxxxxxxxxx> Signed-off-by: Andreas Klinger <ak@xxxxxxxxxxxxx> --- drivers/iio/pressure/mprls0025pa.c | 7 ++----- 1 file changed, 2 insertions(+), 5 deletions(-) diff --git a/drivers/iio/pressure/mprls0025pa.c b/drivers/iio/pressure/mprls0025pa.c index 233cc1dc38ad..63c46592956f 100644 --- a/drivers/iio/pressure/mprls0025pa.c +++ b/drivers/iio/pressure/mprls0025pa.c @@ -375,11 +375,8 @@ static int mpr_probe(struct i2c_client *client) "honeywell,transfer-function %d invalid\n", data->function); } else { - /* when loaded as i2c device we need to use default values */ - dev_notice(dev, "firmware node not found; using defaults\n"); - data->pmin = 0; - data->pmax = 172369; /* 25 psi */ - data->function = MPR_FUNCTION_A; + return dev_err_probe(dev, -EINVAL, + "driver needs to be initialized in the dt\n"); } data->outmin = mpr_func_spec[data->function].output_min; -- 2.41.0