On Sat, Dec 02, 2023 at 06:06:24PM +0200, Petre Rodan wrote: > On Thu, Nov 30, 2023 at 03:33:02PM +0200, Andy Shevchenko wrote: > > On Wed, Nov 29, 2023 at 09:12:52PM +0200, Petre Rodan wrote: > > > On Wed, Nov 29, 2023 at 07:24:31PM +0200, Andy Shevchenko wrote: > > > > > > 437: ret = device_property_read_string(dev, "honeywell,pressure-triplet", > > > &triplet); > > > [..] > > > 455: ret = match_string(hsc_triplet_variants, HSC_VARIANTS_MAX, > > > triplet); > > > if (ret < 0) > > > return dev_err_probe(dev, -EINVAL, > > > "honeywell,pressure-triplet is invalid\n"); > > > > > > hsc->pmin = hsc_range_config[ret].pmin; > > > hsc->pmax = hsc_range_config[ret].pmax; > > > > > > triplet is got via device_property_read_string(), is there some other property > > > function I should be using? > > > > I think I mentioned that API, but for your convenience > > device_property_match_property_string(). > > one of us is not sync-ed with 6.7.0-rc3 :) No, one of us is not synced with subsystem "for-next", which in this case is IIO "togreg" (IIRC) and it definitely has the above mentioned API. -- With Best Regards, Andy Shevchenko