Fix wrongly documented numbering of transfer functions. Fixes: a765c985e696 ("dt-bindings: iio: pressure: Support Honeywell mprls0025pa sensor") Suggested-by: Petre Rodan <petre.rodan@xxxxxxxxxxxxxxx> Signed-off-by: Andreas Klinger <ak@xxxxxxxxxxxxx> --- .../bindings/iio/pressure/honeywell,mprls0025pa.yaml | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml index b31f8120f14e..61775eff1128 100644 --- a/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml +++ b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml @@ -64,9 +64,9 @@ properties: description: | Transfer function which defines the range of valid values delivered by the sensor. - 1 - A, 10% to 90% of 2^24 (1677722 .. 15099494) - 2 - B, 2.5% to 22.5% of 2^24 (419430 .. 3774874) - 3 - C, 20% to 80% of 2^24 (3355443 .. 13421773) + 0 - A, 10% to 90% of 2^24 (1677722 .. 15099494) + 1 - B, 2.5% to 22.5% of 2^24 (419430 .. 3774874) + 2 - C, 20% to 80% of 2^24 (3355443 .. 13421773) $ref: /schemas/types.yaml#/definitions/uint32 vdd-supply: -- 2.39.2