On Thu, 26 Oct 2023 17:44:49 +0200 Javier Carrasco <javier.carrasco.cruz@xxxxxxxxx> wrote: > The HTU21 offers 4 sampling frequencies: 20, 40, 70 and 120, which are > associated to an index that is used to select the right measurement > resolution and its corresponding measurement time. The current > implementation selects the measurement resolution and the temperature > measurement time properly, but it does not select the right humidity > measurement time in all cases. > > In summary, the 40 and 70 humidity measurement times are swapped. > > The reason for that is probably the unusual coding for the measurement > resolution. According to the datasheet, the bits [7,0] of the "user > register" are used as follows to select the bit resolution: > > -------------------------------------------------- > | Bit 7 | Bit 0 | RH | Temp | Trh (us) | Tt (us) | > -------------------------------------------------- > | 0 | 0 | 12 | 14 | 16000 | 50000 | > -------------------------------------------------- > | 0 | 1 | 8 | 12 | 3000 | 13000 | > -------------------------------------------------- > | 1 | 0 | 10 | 13 | 5000 | 25000 | > -------------------------------------------------- > | 1 | 1 | 11 | 11 | 8000 | 7000 | > -------------------------------------------------- > *This table is available in the official datasheet, page 13/21. I have > just appended the times provided in the humidity/temperature tables, > pages 3/21, 5/21. Note that always a pair of resolutions is selected. > > The sampling frequencies [20, 40, 70, 120] are assigned to a linear > index [0..3] which is then coded as follows [1]: > > Index [7,0] > -------------- > idx 0 0,0 > idx 1 1,0 > idx 2 0,1 > idx 3 1,1 > > That is done that way because the temperature measurements are being > used as the reference for the sampling frequency (the frequencies and > the temperature measurement times are correlated), so increasing the > index always reduces the temperature measurement time and its > resolution. Therefore, the temperature measurement time array is as > simple as [50000, 25000, 13000, 7000] > > On the other hand, the humidity resolution cannot follow the same > pattern because of the way it is coded in the "user register", where > both resolutions are selected at the same time. The humidity measurement > time array is the following: [16000, 3000, 5000, 8000], which defines > the following assignments: > > Index [7,0] Trh > ----------------------- > idx 0 0,0 16000 -> right, [0,0] selects 12 bits (Trh = 16000) > idx 1 1,0 3000 -> wrong! [1,0] selects 10 bits (Trh = 5000) > idx 2 0,1 5000 -> wrong! [0,1] selects 8 bits (Trh = 3000) > idx 3 1,1 8000 -> right, [1,1] selects 11 bits (Trh = 8000) > > The times have been ordered as if idx = 1 -> [0,1] and idx = 2 -> [1,0], > which is not the case for the reason explained above. > > So a simple modification is required to obtain the right humidity > measurement time array, swapping the values in the positions 1 and 2. > > The right table should be the following: [16000, 5000, 3000, 8000] > > Fix the humidity measurement time array with the right idex/value > coding. > > [1] The actual code that makes this coding and assigns it to the current > value of the "user register" is the following: > config_reg &= 0x7E; > config_reg |= ((i & 1) << 7) + ((i & 2) >> 1); > > Fixes: d574a87cc311 ("Add meas-spec sensors common part") > Signed-off-by: Javier Carrasco <javier.carrasco.cruz@xxxxxxxxx> Good description. That's horrible :( Applied to the fixes-togreg branch of iio.git and marked for stable. Note however that I probably won't send a fixes pull request until after rc1 is out in about 3 weeks time. Thanks, Jonathan > --- > drivers/iio/common/ms_sensors/ms_sensors_i2c.c | 4 ++-- > 1 file changed, 2 insertions(+), 2 deletions(-) > > diff --git a/drivers/iio/common/ms_sensors/ms_sensors_i2c.c b/drivers/iio/common/ms_sensors/ms_sensors_i2c.c > index 6633b35a94e6..9c9bc77003c7 100644 > --- a/drivers/iio/common/ms_sensors/ms_sensors_i2c.c > +++ b/drivers/iio/common/ms_sensors/ms_sensors_i2c.c > @@ -15,8 +15,8 @@ > /* Conversion times in us */ > static const u16 ms_sensors_ht_t_conversion_time[] = { 50000, 25000, > 13000, 7000 }; > -static const u16 ms_sensors_ht_h_conversion_time[] = { 16000, 3000, > - 5000, 8000 }; > +static const u16 ms_sensors_ht_h_conversion_time[] = { 16000, 5000, > + 3000, 8000 }; > static const u16 ms_sensors_tp_conversion_time[] = { 500, 1100, 2100, > 4100, 8220, 16440 }; > > > --- > base-commit: 611da07b89fdd53f140d7b33013f255bf0ed8f34 > change-id: 20231026-topic-htu21_conversion_time-9ea81e86703f > > Best regards,