On Sat, 2023-09-30 at 10:37 +0100, Conor Dooley wrote: > Hey, > > On Fri, Sep 29, 2023 at 11:08:43PM +0300, Ivan Mikhaylov wrote: > > The hardware binding for i2c current monitoring device with > > overcurrent > > control. > > > > Signed-off-by: Ivan Mikhaylov <fr0st61te@xxxxxxxxx> > > --- > > .../bindings/iio/adc/maxim,max34408.yaml | 101 > > ++++++++++++++++++ > > 1 file changed, 101 insertions(+) > > create mode 100644 > > Documentation/devicetree/bindings/iio/adc/maxim,max34408.yaml > > > > diff --git > > a/Documentation/devicetree/bindings/iio/adc/maxim,max34408.yaml > > b/Documentation/devicetree/bindings/iio/adc/maxim,max34408.yaml > > new file mode 100644 > > index 000000000000..cdf89fa4c80e > > --- /dev/null > > +++ b/Documentation/devicetree/bindings/iio/adc/maxim,max34408.yaml > > @@ -0,0 +1,101 @@ > > +# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause) > > +%YAML 1.2 > > +--- > > +$id: http://devicetree.org/schemas/iio/adc/maxim,max34408.yaml# > > +$schema: http://devicetree.org/meta-schemas/core.yaml# > > + > > +title: Two- and four-channel current monitors with overcurrent > > control > > + > > +maintainers: > > + - Ivan Mikhaylov <fr0st61te@xxxxxxxxx> > > + > > +description: | > > + The MAX34408/MAX34409 are two- and four-channel current monitors > > that are > > + configured and monitored with a standard I2C/SMBus serial > > interface. Each > > + unidirectional current sensor offers precision high-side > > operation with a > > + low full-scale sense voltage. The devices automatically sequence > > through > > + two or four channels and collect the current-sense samples and > > average them > > + to reduce the effect of impulse noise. The raw ADC samples are > > compared to > > + user-programmable digital thresholds to indicate overcurrent > > conditions. > > + Overcurrent conditions trigger a hardware output to provide an > > immediate > > + indication to shut down any necessary external circuitry. > > + > > + Specifications about the devices can be found at: > > + > > https://www.analog.com/media/en/technical-documentation/data-sheets/MAX34408-MAX34409.pdf > > + > > +properties: > > + compatible: > > + enum: > > + - maxim,max34408 > > + - maxim,max34409 > > + > > + reg: > > + maxItems: 1 > > + > > + interrupts: > > + maxItems: 1 > > + > > + maxim,input1-rsense-val-micro-ohms: > > + description: > > + Adjust the Rsense value to monitor higher or lower current > > levels for > > + input 1. > > + enum: [250, 500, 1000, 5000, 10000, 50000, 100000, 200000, > > 500000] > > + default: 1000 > > + > > + maxim,input2-rsense-val-micro-ohms: > > + description: > > + Adjust the Rsense value to monitor higher or lower current > > levels for > > + input 2. > > + enum: [250, 500, 1000, 5000, 10000, 50000, 100000, 200000, > > 500000] > > + default: 1000 > > + > > + maxim,input3-rsense-val-micro-ohms: > > + description: > > + Adjust the Rsense value to monitor higher or lower current > > levels for > > + input 3. > > + enum: [250, 500, 1000, 5000, 10000, 50000, 100000, 200000, > > 500000] > > + default: 1000 > > + > > + maxim,input4-rsense-val-micro-ohms: > > + description: > > + Adjust the Rsense value to monitor higher or lower current > > levels for > > + input 4. > > + enum: [250, 500, 1000, 5000, 10000, 50000, 100000, 200000, > > 500000] > > + default: 1000 > > Having 4 almost identical properties makes it seem like this should > have > some channel nodes, each containing an rsense-micro-ohms type > property. Conor, I'll look through. > > > + > > + maxim,shtdn: > > + description: > > + Shutdown Output. Open-drain output. This output transitions > > to high impedance > > + when any of the digital comparator thresholds are exceeded > > as long as the ENA > > + pin is high. > > + type: boolean > > I don't understand what this property is used for. The description > here, > and below for "ena", read like they are the descriptions in the > datasheet for the pin, rather than how to use the property. > > The drivers don't appear to contain users either - what is the point > of > these properties? ena and shtdn physical pins of hardware, in the previous version Jonathan asked about adding them into yaml even if it's not used in code. should I do it in some other way? > > > + > > + maxim,ena: > > + description: > > + SHTDN Enable Input. CMOS digital input. Connect to GND to > > clear the latch and > > + unconditionally deassert (force low) the SHTDN output and > > reset the shutdown > > + delay. Connect to VDD to enable normal latch operation of > > the SHTDN output. > > + type: boolean > > + > > + supply-vdd: true > > As pointed out by the bot, this is not correct. You need to use a > -supply affix, not a supply-prefix. Oops. Thanks.