On Mon, 25 Sep 2023 14:07:58 +0300 Andy Shevchenko <andy.shevchenko@xxxxxxxxx> wrote: > On Mon, Sep 25, 2023 at 1:26 AM Andreas Kemnade <andreas@xxxxxxxxxxxx> wrote: > > > > Some boards fail in magnetometer probe if flag is not set. > > Which flag? Can you elaborate a bit more? > well see $subj. The level shifter flag. > Does it deserve the Fixes tag? > As there are only certain boards affected, they would also have to add the flag in dtb, I do not think it deservers a Fixes tag. Even in the board I have here, there are basically two mpu9150 connected per cable, only one of them needs the flag. > ... > > > unsigned int val; > > int ret; > > > + ret = regmap_update_bits(st->map, 0x1, 0x80, > > + st->level_shifter ? 0x80 : 0); > > This is a bit cryptic, what does 1 stand for? > Well, I do not find anything in https://invensense.tdk.com/wp-content/uploads/2015/02/MPU-9150-Register-Map.pdf I have just found a similar line in the ancient 3.0 vendor kernel. No symbolic names there. Regards, Andreas