On Wed, 2023-05-03 at 11:58 +0200, Rasmus Villemoes wrote: > On success, ad74413r_get_single_adc_result() returns IIO_VAL_INT aka > 1. So currently, the IIO_CHAN_INFO_PROCESSED case is effectively > equivalent to the IIO_CHAN_INFO_RAW case, and we never call > ad74413r_adc_to_resistance_result() to convert the adc measurement to > ohms. > > Check ret for being negative rather than non-zero. > > Fixes: fea251b6a5dbd (iio: addac: add AD74413R driver) > Signed-off-by: Rasmus Villemoes <linux@xxxxxxxxxxxxxxxxxx> > --- Reviewed-by: Nuno Sa <nuno.sa@xxxxxxxxxx> > drivers/iio/addac/ad74413r.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/drivers/iio/addac/ad74413r.c b/drivers/iio/addac/ad74413r.c > index 07e9f6ae16a8..e3366cf5eb31 100644 > --- a/drivers/iio/addac/ad74413r.c > +++ b/drivers/iio/addac/ad74413r.c > @@ -1007,7 +1007,7 @@ static int ad74413r_read_raw(struct iio_dev *indio_dev, > > ret = ad74413r_get_single_adc_result(indio_dev, chan->channel, > val); > - if (ret) > + if (ret < 0) > return ret; > > ad74413r_adc_to_resistance_result(*val, val);