On 14/04/2023 14:48, Andreas Klinger wrote: > Honeywell mpr is a pressure sensor series. There are many different models with different pressure > ranges, units and transfer functions. > > The range and transfer function need to be set up in the dt. Therefore new properties > honeywell,pmin-pascal, honeywell,pmax-pascal, honeywell,transfer-function are introduced. Please wrap commit message according to Linux coding style / submission process (neither too early nor over the limit): https://elixir.bootlin.com/linux/v5.18-rc4/source/Documentation/process/submitting-patches.rst#L586 > > Add dt-bindings. > > Signed-off-by: Andreas Klinger <ak@xxxxxxxxxxxxx> Patches 2 and 3 are missing. At least they were mentioned in the changelog but this is 1/1. > --- > .../iio/pressure/honeywell,mprls0025pa.yaml | 93 +++++++++++++++++++ > 1 file changed, 93 insertions(+) > create mode 100644 Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml > > diff --git a/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml > new file mode 100644 > index 000000000000..c0eb3c4be16f > --- /dev/null > +++ b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml > @@ -0,0 +1,93 @@ > +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) > +%YAML 1.2 > +--- > +$id: http://devicetree.org/schemas/iio/pressure/honeywell,mprls0025pa.yaml# > +$schema: http://devicetree.org/meta-schemas/core.yaml# > + > +title: Honeywell mpr series pressure sensor > + > +maintainers: > + - Andreas Klinger <ak@xxxxxxxxxxxxx> > + > +description: | > + Honeywell pressure sensor of model mprls0025pa. > + > + This sensor has an I2C and SPI interface. Only the I2C interface is implemented. > + > + There are many models with different pressure ranges available. The vendor calls them "mpr > + series". All of them have the identical programming model and differ in the pressure range, unit Wrap according to Linux coding style, so at 80. > + and transfer function. > + > + To support different models one need to specify the pressure range as well as the transfer > + function. Pressure range needs to be converted from its unit to pascal. > + > + The transfer function defines the ranges of numerical values delivered by the sensor. The minimal > + range value stands for the minimum pressure and the maximum value also for the maximum pressure > + with linear relation inside the range. > + > + Specifications about the devices can be found at: > + https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/ > + pressure-sensors/board-mount-pressure-sensors/micropressure-mpr-series/documents/ > + sps-siot-mpr-series-datasheet-32332628-ciid-172626.pdf > + > +properties: > + compatible: > + const: honeywell,mprls0025pa So this is one compatible for entire family of 96 separate devices. Looks like reasonable compromise, although I will wait for Rob's approval on that. Anyway you need to fix the coding style. Best regards, Krzysztof