From: Carlos Song <carlos.song@xxxxxxx> +/-1200uT is a MAGN sensor full measurement range. Magnetometer scale is the magnetic sensitivity parameter. It is referenced as 0.1uT according to datasheet and magnetometer channel unit is Gauss in sysfs-bus-iio documentation. Gauss and uTesla unit conversion relationship as follows: 0.1uT = 0.001g. Set magnetometer scale and available magnetometer scale as fixed 0.001g. Fixes: 84e5ddd5c46e ("iio: imu: Add support for the FXOS8700 IMU") Signed-off-by: Carlos Song <carlos.song@xxxxxxx> --- Changes for V2: - Modify the magnetometer sensitivity unit to be consistent with the documentation as 0.001g - Rework commit log diff --git a/drivers/iio/imu/fxos8700_core.c b/drivers/iio/imu/fxos8700_core.c index b4baef82f6d5..1780ed99d2f9 100644 --- a/drivers/iio/imu/fxos8700_core.c +++ b/drivers/iio/imu/fxos8700_core.c @@ -352,7 +352,7 @@ static int fxos8700_set_scale(struct fxos8700_data *data, struct device *dev = regmap_get_device(data->regmap); if (t == FXOS8700_MAGN) { - dev_err(dev, "Magnetometer scale is locked at 1200uT\n"); + dev_err(dev, "Magnetometer scale is locked at 0.001g\n"); return -EINVAL; } @@ -397,7 +397,7 @@ static int fxos8700_get_scale(struct fxos8700_data *data, static const int scale_num = ARRAY_SIZE(fxos8700_accel_scale); if (t == FXOS8700_MAGN) { - *uscale = 1200; /* Magnetometer is locked at 1200uT */ + *uscale = 1000; /* Magnetometer is locked at 0.001g */ return 0; } @@ -591,7 +591,7 @@ static IIO_CONST_ATTR(in_accel_sampling_frequency_available, static IIO_CONST_ATTR(in_magn_sampling_frequency_available, "1.5625 6.25 12.5 50 100 200 400 800"); static IIO_CONST_ATTR(in_accel_scale_available, "0.000244 0.000488 0.000976"); -static IIO_CONST_ATTR(in_magn_scale_available, "0.000001200"); +static IIO_CONST_ATTR(in_magn_scale_available, "0.001000"); static struct attribute *fxos8700_attrs[] = { &iio_const_attr_in_accel_sampling_frequency_available.dev_attr.attr, -- 2.34.1