From: Cosmin Tanislav <cosmin.tanislav@xxxxxxxxxx> Excitation cannot be set to auto-range when using a custom thermistor or Steinhart sensor type. Default it to 1000nA to match the driver and remove the auto-range value from the enum. Signed-off-by: Cosmin Tanislav <cosmin.tanislav@xxxxxxxxxx> --- .../bindings/iio/temperature/adi,ltc2983.yaml | 10 ++++++++++ 1 file changed, 10 insertions(+) diff --git a/Documentation/devicetree/bindings/iio/temperature/adi,ltc2983.yaml b/Documentation/devicetree/bindings/iio/temperature/adi,ltc2983.yaml index b603219fb0c9..1b6a11f2aa9d 100644 --- a/Documentation/devicetree/bindings/iio/temperature/adi,ltc2983.yaml +++ b/Documentation/devicetree/bindings/iio/temperature/adi,ltc2983.yaml @@ -378,6 +378,11 @@ patternProperties: adi,sensor-type: const: 26 then: + properties: + adi,excitation-current-nanoamp: + enum: [250, 500, 1000, 5000, 10000, 25000, 50000, 100000, + 250000, 500000, 1000000] + default: 1000 required: - adi,custom-steinhart - if: @@ -385,6 +390,11 @@ patternProperties: adi,sensor-type: const: 27 then: + properties: + adi,excitation-current-nanoamp: + enum: [250, 500, 1000, 5000, 10000, 25000, 50000, 100000, + 250000, 500000, 1000000] + default: 1000 required: - adi,custom-thermistor -- 2.38.1