On Thu, 20 Oct 2022 13:27:05 +0300 Claudiu Beznea <claudiu.beznea@xxxxxxxxxxxxx> wrote: > On SAMA7G5 final chip version there is no need for 5 degrees Celsius > adjustment when computing junction temperature, thus, remove it. > > Fixes: 5ab38b81895c ("iio: adc: at91-sama5d2_adc: add support for temperature sensor") > Signed-off-by: Claudiu Beznea <claudiu.beznea@xxxxxxxxxxxxx> Applied to the fixes-togreg branch of iio.git Thanks, Jonathan > --- > drivers/iio/adc/at91-sama5d2_adc.c | 6 ++---- > 1 file changed, 2 insertions(+), 4 deletions(-) > > diff --git a/drivers/iio/adc/at91-sama5d2_adc.c b/drivers/iio/adc/at91-sama5d2_adc.c > index 33e251552214..870f4cb60923 100644 > --- a/drivers/iio/adc/at91-sama5d2_adc.c > +++ b/drivers/iio/adc/at91-sama5d2_adc.c > @@ -2307,11 +2307,9 @@ static int at91_adc_temp_sensor_init(struct at91_adc_state *st, > clb->p6 = buf[AT91_ADC_TS_CLB_IDX_P6]; > > /* > - * We prepare here the conversion to milli and also add constant > - * factor (5 degrees Celsius) to p1 here to avoid doing it on > - * hotpath. > + * We prepare here the conversion to milli to avoid doing it on hotpath. > */ > - clb->p1 = clb->p1 * 1000 + 5000; > + clb->p1 = clb->p1 * 1000; > > free_buf: > kfree(buf);