From: Crt Mori <cmo@xxxxxxxxxxx> The sensor can operate in lower power modes and even make measurements when in those lower powered modes. The decision was taken that if measurement is not requested within 2 seconds the sensor will remain in SLEEP_STEP power mode, where measurements are triggered on request with setting the start of measurement bit (SOB). In this mode the measurements are taking a bit longer because we need to start it and complete it. Currently, in continuous mode we read ready data and this mode is activated if sensor measurement is requested within 2 seconds. The suspend timeout is increased to 6 seconds (instead of 3 before), because that enables more measurements in lower power mode (SLEEP_STEP), with the lowest refresh rate (2 seconds). Signed-off-by: Crt Mori <cmo@xxxxxxxxxxx> --- drivers/iio/temperature/mlx90632.c | 341 ++++++++++++++++++++++++----- 1 file changed, 287 insertions(+), 54 deletions(-) diff --git a/drivers/iio/temperature/mlx90632.c b/drivers/iio/temperature/mlx90632.c index 549c0ab5c2be..80497d9bc4e9 100644 --- a/drivers/iio/temperature/mlx90632.c +++ b/drivers/iio/temperature/mlx90632.c @@ -6,11 +6,14 @@ * * Driver for the Melexis MLX90632 I2C 16-bit IR thermopile sensor */ +#include <linux/bitfield.h> #include <linux/delay.h> +#include <linux/device.h> #include <linux/err.h> #include <linux/gpio/consumer.h> #include <linux/i2c.h> #include <linux/iopoll.h> +#include <linux/jiffies.h> #include <linux/kernel.h> #include <linux/limits.h> #include <linux/mod_devicetable.h> @@ -55,6 +58,12 @@ #define MLX90632_EE_Ha 0x2481 /* Ha customer calib value reg 16bit */ #define MLX90632_EE_Hb 0x2482 /* Hb customer calib value reg 16bit */ +#define MLX90632_EE_MEDICAL_MEAS1 0x24E1 /* Medical measurement 1 16bit */ +#define MLX90632_EE_MEDICAL_MEAS2 0x24E2 /* Medical measurement 2 16bit */ +#define MLX90632_EE_EXTENDED_MEAS1 0x24F1 /* Extended measurement 1 16bit */ +#define MLX90632_EE_EXTENDED_MEAS2 0x24F2 /* Extended measurement 2 16bit */ +#define MLX90632_EE_EXTENDED_MEAS3 0x24F3 /* Extended measurement 3 16bit */ + /* Register addresses - volatile */ #define MLX90632_REG_I2C_ADDR 0x3000 /* Chip I2C address register */ @@ -62,13 +71,16 @@ #define MLX90632_REG_CONTROL 0x3001 /* Control Register address */ #define MLX90632_CFG_PWR_MASK GENMASK(2, 1) /* PowerMode Mask */ #define MLX90632_CFG_MTYP_MASK GENMASK(8, 4) /* Meas select Mask */ +#define MLX90632_CFG_SOB_MASK BIT(11) /* PowerModes statuses */ #define MLX90632_PWR_STATUS(ctrl_val) (ctrl_val << 1) #define MLX90632_PWR_STATUS_HALT MLX90632_PWR_STATUS(0) /* hold */ -#define MLX90632_PWR_STATUS_SLEEP_STEP MLX90632_PWR_STATUS(1) /* sleep step*/ +#define MLX90632_PWR_STATUS_SLEEP_STEP MLX90632_PWR_STATUS(1) /* sleep step */ #define MLX90632_PWR_STATUS_STEP MLX90632_PWR_STATUS(2) /* step */ -#define MLX90632_PWR_STATUS_CONTINUOUS MLX90632_PWR_STATUS(3) /* continuous*/ +#define MLX90632_PWR_STATUS_CONTINUOUS MLX90632_PWR_STATUS(3) /* continuous */ + +#define MLX90632_EE_RR GENMASK(10, 8) /* Only Refresh Rate bits */ /* Measurement types */ #define MLX90632_MTYP_MEDICAL 0 @@ -116,8 +128,9 @@ #define MLX90632_REF_12 12LL /* ResCtrlRef value of Ch 1 or Ch 2 */ #define MLX90632_REF_3 12LL /* ResCtrlRef value of Channel 3 */ #define MLX90632_MAX_MEAS_NUM 31 /* Maximum measurements in list */ -#define MLX90632_SLEEP_DELAY_MS 3000 /* Autosleep delay */ +#define MLX90632_SLEEP_DELAY_MS 6000 /* Autosleep delay */ #define MLX90632_EXTENDED_LIMIT 27000 /* Extended mode raw value limit */ +#define MLX90632_MEAS_MAX_TIME 2000 /* Max measurement time in ms for the lowest refresh rate */ /** * struct mlx90632_data - private data for the MLX90632 device @@ -130,6 +143,9 @@ * @object_ambient_temperature: Ambient temperature at object (might differ of * the ambient temperature of sensor. * @regulator: Regulator of the device + * @powerstatus: Current POWER status of the device + * @interaction_ts: Timestamp of the last temperature read that is used + * for power management in jiffies */ struct mlx90632_data { struct i2c_client *client; @@ -139,6 +155,8 @@ struct mlx90632_data { u8 mtyp; u32 object_ambient_temperature; struct regulator *regulator; + int powerstatus; + unsigned long interaction_ts; }; static const struct regmap_range mlx90632_volatile_reg_range[] = { @@ -158,6 +176,8 @@ static const struct regmap_range mlx90632_read_reg_range[] = { regmap_reg_range(MLX90632_EE_VERSION, MLX90632_EE_Ka), regmap_reg_range(MLX90632_EE_CTRL, MLX90632_EE_I2C_ADDR), regmap_reg_range(MLX90632_EE_Ha, MLX90632_EE_Hb), + regmap_reg_range(MLX90632_EE_MEDICAL_MEAS1, MLX90632_EE_MEDICAL_MEAS2), + regmap_reg_range(MLX90632_EE_EXTENDED_MEAS1, MLX90632_EE_EXTENDED_MEAS3), regmap_reg_range(MLX90632_REG_I2C_ADDR, MLX90632_REG_CONTROL), regmap_reg_range(MLX90632_REG_I2C_CMD, MLX90632_REG_I2C_CMD), regmap_reg_range(MLX90632_REG_STATUS, MLX90632_REG_STATUS), @@ -198,16 +218,38 @@ static const struct regmap_config mlx90632_regmap = { static s32 mlx90632_pwr_set_sleep_step(struct regmap *regmap) { - return regmap_update_bits(regmap, MLX90632_REG_CONTROL, - MLX90632_CFG_PWR_MASK, - MLX90632_PWR_STATUS_SLEEP_STEP); + struct mlx90632_data *data = + iio_priv(dev_get_drvdata(regmap_get_device(regmap))); + s32 ret; + + if (data->powerstatus == MLX90632_PWR_STATUS_SLEEP_STEP) + return 0; + + ret = regmap_write_bits(regmap, MLX90632_REG_CONTROL, MLX90632_CFG_PWR_MASK, + MLX90632_PWR_STATUS_SLEEP_STEP); + if (ret < 0) + return ret; + + data->powerstatus = MLX90632_PWR_STATUS_SLEEP_STEP; + return ret; } static s32 mlx90632_pwr_continuous(struct regmap *regmap) { - return regmap_update_bits(regmap, MLX90632_REG_CONTROL, - MLX90632_CFG_PWR_MASK, - MLX90632_PWR_STATUS_CONTINUOUS); + struct mlx90632_data *data = + iio_priv(dev_get_drvdata(regmap_get_device(regmap))); + s32 ret; + + if (data->powerstatus == MLX90632_PWR_STATUS_CONTINUOUS) + return 0; + + ret = regmap_write_bits(regmap, MLX90632_REG_CONTROL, MLX90632_CFG_PWR_MASK, + MLX90632_PWR_STATUS_CONTINUOUS); + if (ret < 0) + return ret; + + data->powerstatus = MLX90632_PWR_STATUS_CONTINUOUS; + return ret; } /** @@ -219,6 +261,63 @@ static void mlx90632_reset_delay(void) usleep_range(150, 200); } +static int mlx90632_get_measurement_time(struct regmap *regmap, u16 meas) +{ + unsigned int reg; + int ret; + + ret = regmap_read(regmap, meas, ®); + if (ret < 0) + return ret; + + return MLX90632_MEAS_MAX_TIME >> FIELD_GET(MLX90632_EE_RR, reg); +} + +static int mlx90632_calculate_dataset_ready_time(struct mlx90632_data *data) +{ + unsigned int refresh_time; + int ret; + + if (data->mtyp == MLX90632_MTYP_MEDICAL) { + ret = mlx90632_get_measurement_time(data->regmap, + MLX90632_EE_MEDICAL_MEAS1); + if (ret < 0) + return ret; + + refresh_time = ret; + + ret = mlx90632_get_measurement_time(data->regmap, + MLX90632_EE_MEDICAL_MEAS2); + if (ret < 0) + return ret; + + refresh_time += ret; + } else { + ret = mlx90632_get_measurement_time(data->regmap, + MLX90632_EE_EXTENDED_MEAS1); + if (ret < 0) + return ret; + + refresh_time = ret; + + ret = mlx90632_get_measurement_time(data->regmap, + MLX90632_EE_EXTENDED_MEAS2); + if (ret < 0) + return ret; + + refresh_time += ret; + + ret = mlx90632_get_measurement_time(data->regmap, + MLX90632_EE_EXTENDED_MEAS3); + if (ret < 0) + return ret; + + refresh_time += ret; + } + + return refresh_time; +} + /** * mlx90632_perform_measurement() - Trigger and retrieve current measurement cycle * @data: pointer to mlx90632_data object containing regmap information @@ -249,26 +348,75 @@ static int mlx90632_perform_measurement(struct mlx90632_data *data) return (reg_status & MLX90632_STAT_CYCLE_POS) >> 2; } -static int mlx90632_set_meas_type(struct regmap *regmap, u8 type) +/** + * mlx90632_perform_measurement_burst() - Trigger and retrieve current measurement + * cycle in step sleep mode + * @data: pointer to mlx90632_data object containing regmap information + * + * Perform a measurement and return 2 as measurement cycle position reported + * by sensor. This is a blocking function for amount dependent on the sensor + * refresh rate. + */ +static int mlx90632_perform_measurement_burst(struct mlx90632_data *data) { + unsigned int reg_status; int ret; - if ((type != MLX90632_MTYP_MEDICAL) && (type != MLX90632_MTYP_EXTENDED)) - return -EINVAL; + ret = regmap_write_bits(data->regmap, MLX90632_REG_CONTROL, + MLX90632_CFG_SOB_MASK, MLX90632_CFG_SOB_MASK); + if (ret < 0) + return ret; - ret = regmap_write(regmap, MLX90632_REG_I2C_CMD, MLX90632_RESET_CMD); + ret = mlx90632_calculate_dataset_ready_time(data); + if (ret < 0) + return ret; + + msleep(ret); /* Wait minimum time for dataset to be ready */ + + ret = regmap_read_poll_timeout(data->regmap, MLX90632_REG_STATUS, + reg_status, + (reg_status & MLX90632_STAT_BUSY) == 0, + 10000, 100 * 10000); + if (ret < 0) { + dev_err(&data->client->dev, "data not ready"); + return -ETIMEDOUT; + } + + return 2; +} + +static int mlx90632_set_meas_type(struct mlx90632_data *data, u8 type) +{ + int current_powerstatus; + int ret; + + if (data->mtyp == type) + return 0; + + current_powerstatus = data->powerstatus; + ret = mlx90632_pwr_continuous(data->regmap); + if (ret < 0) + return ret; + + ret = regmap_write(data->regmap, MLX90632_REG_I2C_CMD, MLX90632_RESET_CMD); if (ret < 0) return ret; mlx90632_reset_delay(); - ret = regmap_write_bits(regmap, MLX90632_REG_CONTROL, + ret = regmap_update_bits(data->regmap, MLX90632_REG_CONTROL, (MLX90632_CFG_MTYP_MASK | MLX90632_CFG_PWR_MASK), (MLX90632_MTYP_STATUS(type) | MLX90632_PWR_STATUS_HALT)); if (ret < 0) return ret; - return mlx90632_pwr_continuous(regmap); + data->mtyp = type; + data->powerstatus = MLX90632_PWR_STATUS_HALT; + + if (current_powerstatus == MLX90632_PWR_STATUS_SLEEP_STEP) + return mlx90632_pwr_set_sleep_step(data->regmap); + + return mlx90632_pwr_continuous(data->regmap); } static int mlx90632_channel_new_select(int perform_ret, uint8_t *channel_new, @@ -355,11 +503,30 @@ static int mlx90632_read_all_channel(struct mlx90632_data *data, s32 ret, measurement; mutex_lock(&data->lock); - measurement = mlx90632_perform_measurement(data); - if (measurement < 0) { - ret = measurement; + ret = mlx90632_set_meas_type(data, MLX90632_MTYP_MEDICAL); + if (ret < 0) + goto read_unlock; + + switch (data->powerstatus) { + case MLX90632_PWR_STATUS_CONTINUOUS: + measurement = mlx90632_perform_measurement(data); + if (measurement < 0) { + ret = measurement; + goto read_unlock; + } + break; + case MLX90632_PWR_STATUS_SLEEP_STEP: + measurement = mlx90632_perform_measurement_burst(data); + if (measurement < 0) { + ret = measurement; + goto read_unlock; + } + break; + default: + ret = -EOPNOTSUPP; goto read_unlock; } + ret = mlx90632_read_ambient_raw(data->regmap, ambient_new_raw, ambient_old_raw); if (ret < 0) @@ -441,14 +608,20 @@ static int mlx90632_read_all_channel_extended(struct mlx90632_data *data, s16 *o s32 ret, meas; mutex_lock(&data->lock); - ret = mlx90632_set_meas_type(data->regmap, MLX90632_MTYP_EXTENDED); + ret = mlx90632_set_meas_type(data, MLX90632_MTYP_EXTENDED); if (ret < 0) goto read_unlock; - ret = read_poll_timeout(mlx90632_perform_measurement, meas, meas == 19, - 50000, 800000, false, data); - if (ret != 0) - goto read_unlock; + if (data->powerstatus == MLX90632_PWR_STATUS_CONTINUOUS) { + ret = read_poll_timeout(mlx90632_perform_measurement, meas, meas == 19, + 50000, 800000, false, data); + if (ret) + goto read_unlock; + } else if (data->powerstatus == MLX90632_PWR_STATUS_SLEEP_STEP) { + ret = mlx90632_perform_measurement_burst(data); + if (ret < 0) + goto read_unlock; + } ret = mlx90632_read_object_raw_extended(data->regmap, object_new_raw); if (ret < 0) @@ -457,8 +630,6 @@ static int mlx90632_read_all_channel_extended(struct mlx90632_data *data, s16 *o ret = mlx90632_read_ambient_raw_extended(data->regmap, ambient_new_raw, ambient_old_raw); read_unlock: - (void) mlx90632_set_meas_type(data->regmap, MLX90632_MTYP_MEDICAL); - mutex_unlock(&data->lock); return ret; } @@ -743,12 +914,47 @@ static int mlx90632_calc_ambient_dsp105(struct mlx90632_data *data, int *val) return ret; } +/** + * mlx90632_pm_interraction_wakeup() - Measure time between user interactions to change powermode + * @data: pointer to mlx90632_data object containing interaction_ts information + * + * Switch to continuous mode when interaction is faster than MLX90632_MEAS_MAX_TIME. Update the + * interaction_ts for each function call with the jiffies to enable measurement between function + * calls. Initial value of the interaction_ts needs to be set before this function call. + */ +static int mlx90632_pm_interraction_wakeup(struct mlx90632_data *data) +{ + unsigned long now; + int ret; + + now = jiffies; + if (time_in_range(now, data->interaction_ts, + data->interaction_ts + + msecs_to_jiffies(MLX90632_MEAS_MAX_TIME + 100))) { + if (data->powerstatus == MLX90632_PWR_STATUS_SLEEP_STEP) { + ret = mlx90632_pwr_continuous(data->regmap); + if (ret < 0) + return ret; + } + } + + data->interaction_ts = now; + + return 0; +} + static int mlx90632_read_raw(struct iio_dev *indio_dev, struct iio_chan_spec const *channel, int *val, int *val2, long mask) { struct mlx90632_data *data = iio_priv(indio_dev); int ret; + int cr; + + pm_runtime_get_sync(&data->client->dev); + ret = mlx90632_pm_interraction_wakeup(data); + if (ret < 0) + goto mlx90632_read_raw_pm; switch (mask) { case IIO_CHAN_INFO_PROCESSED: @@ -756,16 +962,22 @@ static int mlx90632_read_raw(struct iio_dev *indio_dev, case IIO_MOD_TEMP_AMBIENT: ret = mlx90632_calc_ambient_dsp105(data, val); if (ret < 0) - return ret; - return IIO_VAL_INT; + goto mlx90632_read_raw_pm; + + ret = IIO_VAL_INT; + break; case IIO_MOD_TEMP_OBJECT: ret = mlx90632_calc_object_dsp105(data, val); if (ret < 0) - return ret; - return IIO_VAL_INT; + goto mlx90632_read_raw_pm; + + ret = IIO_VAL_INT; + break; default: - return -EINVAL; + ret = -EINVAL; + break; } + break; case IIO_CHAN_INFO_CALIBEMISSIVITY: if (data->emissivity == 1000) { *val = 1; @@ -774,13 +986,21 @@ static int mlx90632_read_raw(struct iio_dev *indio_dev, *val = 0; *val2 = data->emissivity * 1000; } - return IIO_VAL_INT_PLUS_MICRO; + ret = IIO_VAL_INT_PLUS_MICRO; + break; case IIO_CHAN_INFO_CALIBAMBIENT: *val = data->object_ambient_temperature; - return IIO_VAL_INT; + ret = IIO_VAL_INT; + break; default: - return -EINVAL; + ret = -EINVAL; + break; } + +mlx90632_read_raw_pm: + pm_runtime_mark_last_busy(&data->client->dev); + pm_runtime_put_autosuspend(&data->client->dev); + return ret; } static int mlx90632_write_raw(struct iio_dev *indio_dev, @@ -902,6 +1122,7 @@ static int mlx90632_probe(struct i2c_client *client, mlx90632->client = client; mlx90632->regmap = regmap; mlx90632->mtyp = MLX90632_MTYP_MEDICAL; + mlx90632->powerstatus = MLX90632_PWR_STATUS_HALT; mutex_init(&mlx90632->lock); indio_dev->name = id->name; @@ -961,16 +1182,19 @@ static int mlx90632_probe(struct i2c_client *client, mlx90632->emissivity = 1000; mlx90632->object_ambient_temperature = 25000; /* 25 degrees milliCelsius */ + mlx90632->interaction_ts = jiffies; /* Set initial value */ - pm_runtime_disable(&client->dev); + pm_runtime_get_noresume(&client->dev); ret = pm_runtime_set_active(&client->dev); if (ret < 0) { mlx90632_sleep(mlx90632); return ret; } - pm_runtime_enable(&client->dev); + + devm_pm_runtime_enable(&client->dev); pm_runtime_set_autosuspend_delay(&client->dev, MLX90632_SLEEP_DELAY_MS); pm_runtime_use_autosuspend(&client->dev); + pm_runtime_put_autosuspend(&client->dev); return iio_device_register(indio_dev); } @@ -978,16 +1202,8 @@ static int mlx90632_probe(struct i2c_client *client, static int mlx90632_remove(struct i2c_client *client) { struct iio_dev *indio_dev = i2c_get_clientdata(client); - struct mlx90632_data *data = iio_priv(indio_dev); iio_device_unregister(indio_dev); - - pm_runtime_disable(&client->dev); - pm_runtime_set_suspended(&client->dev); - pm_runtime_put_noidle(&client->dev); - - mlx90632_sleep(data); - return 0; } @@ -1003,30 +1219,47 @@ static const struct of_device_id mlx90632_of_match[] = { }; MODULE_DEVICE_TABLE(of, mlx90632_of_match); -static int __maybe_unused mlx90632_pm_suspend(struct device *dev) +static int mlx90632_pm_suspend(struct device *dev) { - struct iio_dev *indio_dev = i2c_get_clientdata(to_i2c_client(dev)); - struct mlx90632_data *data = iio_priv(indio_dev); + struct mlx90632_data *data = iio_priv(dev_get_drvdata(dev)); + int ret; + + ret = mlx90632_pwr_set_sleep_step(data->regmap); + if (ret < 0) + return ret; + + ret = regulator_disable(data->regulator); + if (ret < 0) + dev_err(regmap_get_device(data->regmap), + "Failed to disable power regulator: %d\n", ret); - return mlx90632_sleep(data); + return ret; } -static int __maybe_unused mlx90632_pm_resume(struct device *dev) +static int mlx90632_pm_resume(struct device *dev) { - struct iio_dev *indio_dev = i2c_get_clientdata(to_i2c_client(dev)); - struct mlx90632_data *data = iio_priv(indio_dev); + struct mlx90632_data *data = iio_priv(dev_get_drvdata(dev)); - return mlx90632_wakeup(data); + return mlx90632_enable_regulator(data); } -static UNIVERSAL_DEV_PM_OPS(mlx90632_pm_ops, mlx90632_pm_suspend, - mlx90632_pm_resume, NULL); +static int mlx90632_pm_runtime_suspend(struct device *dev) +{ + struct mlx90632_data *data = iio_priv(dev_get_drvdata(dev)); + + return mlx90632_pwr_set_sleep_step(data->regmap); +} + +const struct dev_pm_ops mlx90632_pm_ops = { + SYSTEM_SLEEP_PM_OPS(mlx90632_pm_suspend, mlx90632_pm_resume) + RUNTIME_PM_OPS(mlx90632_pm_runtime_suspend, NULL, NULL) +}; static struct i2c_driver mlx90632_driver = { .driver = { .name = "mlx90632", .of_match_table = mlx90632_of_match, - .pm = &mlx90632_pm_ops, + .pm = pm_ptr(&mlx90632_pm_ops), }, .probe = mlx90632_probe, .remove = mlx90632_remove, -- 2.34.1