Re: [PATCH v6 3/9] iio: pressure: bmp280: Simplify bmp280 calibration data reading

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Tue, 13 Sep 2022 01:46:42 +0200
Angel Iglesias <ang.iglesiasg@xxxxxxxxx> wrote:

> On bmp280 and bme280, the temperature and pressure calibration parameters
> are available on a contiguous memory region. Considering this arrangement,
> simplified the calibration reading function by using only one buffer
> to read in batch temperature and pressure registers.
> 
> Signed-off-by: Angel Iglesias <ang.iglesiasg@xxxxxxxxx>
Applied.  Apparently we have a plane, so I'll stop here for now...

Jonathan

> ---
>  drivers/iio/pressure/bmp280-core.c | 58 ++++++++++++------------------
>  drivers/iio/pressure/bmp280.h      |  3 ++
>  2 files changed, 26 insertions(+), 35 deletions(-)
> 
> diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c
> index 0ba4ff999f33..4793bcd9f0b3 100644
> --- a/drivers/iio/pressure/bmp280-core.c
> +++ b/drivers/iio/pressure/bmp280-core.c
> @@ -128,8 +128,7 @@ struct bmp280_chip_info {
>   * These enums are used for indexing into the array of compensation
>   * parameters for BMP280.
>   */
> -enum { T1, T2, T3 };
> -enum { P1, P2, P3, P4, P5, P6, P7, P8, P9 };
> +enum { T1, T2, T3, P1, P2, P3, P4, P5, P6, P7, P8, P9 };
>  
>  static const struct iio_chan_spec bmp280_channels[] = {
>  	{
> @@ -153,8 +152,7 @@ static int bmp280_read_calib(struct bmp280_data *data,
>  			     struct bmp280_calib *calib,
>  			     unsigned int chip)
>  {
> -	__le16 p_buf[BMP280_COMP_PRESS_REG_COUNT / 2];
> -	__le16 t_buf[BMP280_COMP_TEMP_REG_COUNT / 2];
> +	__le16 c_buf[BMP280_CONTIGUOUS_CALIB_REGS / 2];
>  	struct device *dev = data->dev;
>  	unsigned int tmp;
>  	__le16 l16;
> @@ -162,43 +160,33 @@ static int bmp280_read_calib(struct bmp280_data *data,
>  	int ret;
>  
>  
> -	/* Read temperature calibration values. */
> +	/* Read temperature and pressure calibration values. */
>  	ret = regmap_bulk_read(data->regmap, BMP280_REG_COMP_TEMP_START,
> -			       t_buf, BMP280_COMP_TEMP_REG_COUNT);
> +			       c_buf, sizeof(c_buf));
>  	if (ret < 0) {
>  		dev_err(data->dev,
> -			"failed to read temperature calibration parameters\n");
> +			"failed to read temperature and pressure calibration parameters\n");
>  		return ret;
>  	}
>  
> -	/* Toss the temperature calibration data into the entropy pool */
> -	add_device_randomness(t_buf, sizeof(t_buf));
> -
> -	calib->T1 = le16_to_cpu(t_buf[T1]);
> -	calib->T2 = le16_to_cpu(t_buf[T2]);
> -	calib->T3 = le16_to_cpu(t_buf[T3]);
> -
> -	/* Read pressure calibration values. */
> -	ret = regmap_bulk_read(data->regmap, BMP280_REG_COMP_PRESS_START,
> -			       p_buf, BMP280_COMP_PRESS_REG_COUNT);
> -	if (ret < 0) {
> -		dev_err(data->dev,
> -			"failed to read pressure calibration parameters\n");
> -		return ret;
> -	}
> -
> -	/* Toss the pressure calibration data into the entropy pool */
> -	add_device_randomness(p_buf, sizeof(p_buf));
> -
> -	calib->P1 = le16_to_cpu(p_buf[P1]);
> -	calib->P2 = le16_to_cpu(p_buf[P2]);
> -	calib->P3 = le16_to_cpu(p_buf[P3]);
> -	calib->P4 = le16_to_cpu(p_buf[P4]);
> -	calib->P5 = le16_to_cpu(p_buf[P5]);
> -	calib->P6 = le16_to_cpu(p_buf[P6]);
> -	calib->P7 = le16_to_cpu(p_buf[P7]);
> -	calib->P8 = le16_to_cpu(p_buf[P8]);
> -	calib->P9 = le16_to_cpu(p_buf[P9]);
> +	/* Toss the temperature and pressure calibration data into the entropy pool */
> +	add_device_randomness(c_buf, sizeof(c_buf));
> +
> +	/* Parse temperature calibration values. */
> +	calib->T1 = le16_to_cpu(c_buf[T1]);
> +	calib->T2 = le16_to_cpu(c_buf[T2]);
> +	calib->T3 = le16_to_cpu(c_buf[T3]);
> +
> +	/* Parse pressure calibration values. */
> +	calib->P1 = le16_to_cpu(c_buf[P1]);
> +	calib->P2 = le16_to_cpu(c_buf[P2]);
> +	calib->P3 = le16_to_cpu(c_buf[P3]);
> +	calib->P4 = le16_to_cpu(c_buf[P4]);
> +	calib->P5 = le16_to_cpu(c_buf[P5]);
> +	calib->P6 = le16_to_cpu(c_buf[P6]);
> +	calib->P7 = le16_to_cpu(c_buf[P7]);
> +	calib->P8 = le16_to_cpu(c_buf[P8]);
> +	calib->P9 = le16_to_cpu(c_buf[P9]);
>  
>  	/*
>  	 * Read humidity calibration values.
> diff --git a/drivers/iio/pressure/bmp280.h b/drivers/iio/pressure/bmp280.h
> index 4a501836d27a..03a539223417 100644
> --- a/drivers/iio/pressure/bmp280.h
> +++ b/drivers/iio/pressure/bmp280.h
> @@ -37,6 +37,9 @@
>  
>  #define BMP280_COMP_H5_MASK		GENMASK(15, 4)
>  
> +#define BMP280_CONTIGUOUS_CALIB_REGS	(BMP280_COMP_TEMP_REG_COUNT + \
> +					 BMP280_COMP_PRESS_REG_COUNT)
> +
>  #define BMP280_FILTER_MASK		GENMASK(4, 2)
>  #define BMP280_FILTER_OFF		0
>  #define BMP280_FILTER_2X		1




[Index of Archives]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Input]     [Linux Kernel]     [Linux SCSI]     [X.org]

  Powered by Linux