On Tue, 13 Sep 2022 00:26:44 +0200 Angel Iglesias <ang.iglesiasg@xxxxxxxxx> wrote: > Updated links for BMP280 and BME280 datasheets on Bosch website. > Datasheet of BMP180 is no longer available on the manufacturer's website, > changed the link to a copy hosted by a third party. > > Changelog in v2: > * Added a notice about the situation with bmp180 datasheet and list > missing changes from newer versions. Change log needs to be below the --- We don't want that level of detail in the git logs. I tidied that up whilst applying. Also, it's not a good idea to have new versions as replies to older ones. Leads to very deep nesting in email threads and generally makes things less readable. Just post a fresh series each time. Applied to the togreg branch of iio.git and pushed out as testing for 0-day to see if it can find anything (rather unlikely on this patch!) Jonathan > > Reported-by: Andy Shevchenko <andy.shevchenko@xxxxxxxxx> > Signed-off-by: Angel Iglesias <ang.iglesiasg@xxxxxxxxx> > --- > drivers/iio/pressure/bmp280-core.c | 12 +++++++++--- > 1 file changed, 9 insertions(+), 3 deletions(-) > > diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c > index fe7aa81e7cc9..01cd32003ca8 100644 > --- a/drivers/iio/pressure/bmp280-core.c > +++ b/drivers/iio/pressure/bmp280-core.c > @@ -9,9 +9,15 @@ > * Driver for Bosch Sensortec BMP180 and BMP280 digital pressure sensor. > * > * Datasheet: > - * https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BMP180-DS000-121.pdf > - * https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BMP280-DS001-12.pdf > - * https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BME280_DS001-11.pdf > + * https://cdn-shop.adafruit.com/datasheets/BST-BMP180-DS000-09.pdf > + * https://www.bosch-sensortec.com/media/boschsensortec/downloads/datasheets/bst-bmp280-ds001.pdf > + * https://www.bosch-sensortec.com/media/boschsensortec/downloads/datasheets/bst-bme280-ds002.pdf > + * > + * Notice: > + * The link to the bmp180 datasheet points to an outdated version missing these changes: > + * - Changed document referral from ANP015 to BST-MPS-AN004-00 on page 26 > + * - Updated equation for B3 param on section 3.5 to ((((long)AC1 * 4 + X3) << oss) + 2) / 4 > + * - Updated RoHS directive to 2011/65/EU effective 8 June 2011 on page 26 > */ > > #define pr_fmt(fmt) "bmp280: " fmt > > base-commit: 2f61ff8272967c9bdcba810aa978170814b08f7c