[PATCH v2 0/3] units: complement the set of Hz units

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



During msa311 accel IIO driver development

https://lore.kernel.org/linux-iio/20220616104211.9257-1-ddrokosov@xxxxxxxxxxxxxx/

Andy requested to use proper units in the hz->ms calculation. Current
units.h header doesn't have milli, micro and nano HZ coefficients, so
some drivers (in the IIO subsystem) implement their own copies for that.

The current patchset resolves such a problem and intoduces general
MILLIHZ_PER_HZ, UHZ_PER_HZ and NHZ_PER_HZ definitions in the units.h, and
fixes all drivers which duplicate these units.

Changes v1->v2:
    - changed MHZ_PER_HZ to a different name as Andy suggested
      (suppose MILLIHZ_PER_HZ is good enough)

Dmitry Rokosov (3):
  units: complement the set of Hz units
  iio: accel: adxl345: use HZ macro from units.h
  iio: common: scmi_sensors: use HZ macro from units.h

 drivers/iio/accel/adxl345_core.c           | 2 +-
 drivers/iio/common/scmi_sensors/scmi_iio.c | 2 +-
 include/linux/units.h                      | 3 +++
 3 files changed, 5 insertions(+), 2 deletions(-)

-- 
2.36.0