On Sat, Jul 23, 2022 at 7:40 PM Angel Iglesias <ang.iglesiasg@xxxxxxxxx> wrote: > > Allows sampling frequency and IIR filter coefficients configuration > using sysfs ABI. > > The IIR filter coefficient is configurable using the sysfs attribute > "filter_low_pass_3db_frequency". > > Signed-off-by: Angel Iglesias <ang.iglesiasg@xxxxxxxxx> > Reported-by: Andy Shevchenko <andy.shevchenko@xxxxxxxxx> # uninit var Bugs in new features can't have Reported-by tag. If you wish to give credit, use a cover letter / changelog. ... > + /* > + * Configuration errors are detected on the fly during a measurement The configurations > + * cycle. If the sampling frequency is too low, it's faster to reset > + * measurement loop than wait until next measurement is due. the measurement the next > + * Resets sensor measurement loop toggling between sleep and normal > + * operating modes. > + */ -- With Best Regards, Andy Shevchenko