From: Alexandru Tachici <alexandru.tachici@xxxxxxxxxx> Some sigma-delta chips support sampling of multiple channels in continuous mode. When the operating with more than one channel enabled, the channel sequencer cycles through the enabled channels in sequential order, from first channel to the last one. If a channel is disabled, it is skipped by the sequencer. If more than one channel is used in continuous mode, instruct the device to append the status to the SPI transfer (1 extra byte) every time we receive a sample. All sigma-delta chips possessing a sampling sequencer have this ability. Inside the status register there will be the number of the converted channel. In this way, even if the CPU won't keep up with the sampling rate, it won't send to userspace wrong channel samples. 1. Removed the 1 byte .shift from channel spec in AD7124, it confuses userspace apps (no need to shift right). 2. Add update_scan_mode to AD7124, it is required in order to enable/disable multiple channels at once 3. Add update_scan_mode to AD7192, it is required in order to enable/disable multiple channels at once 4. Add sequencer support for sigma_delta library. 5. Add sigma_delta_info values and callbacks for sequencer support in AD7124. 6. Add sigma_delta_info values and callbacks for sequencer support in AD7192. Alexandru Tachici (5): iio: adc: ad7124: Remove shift from scan_type iio: adc: ad7124: Add update_scan_mode iio: adc: ad7192: Add update_scan_mode iio: adc: ad7124: add sequencer support iio: adc: ad7192: add sequencer support Lars-Peter Clausen (1): iio: adc: ad_sigma_delta: Add sequencer support Changelog V2 -> V3: - ad_sd_buffer_postenable(), aligned (slot * storagebits) to 8 bytes - devm_krealloc instead of krealloc for samples_buf in ad_sd_buffer_postenable() - in ad_sigma_delta_append_status, check return value before setting .status_appended - iio: adc: ad_sigma_delta: Add sequencer support: added explanations on desynchronization checking and recovery - in ad7124_append_status() modify st->adc_control after write has taken place without errors - in ad7124_update_scan_mode() take cfg mutex only once instead of every time a set_channel happens - in ad7192_disable_all() modify st->conf after write taken place without errors - in ad7192_append_status() modify st->mode after write taken place without errors drivers/iio/adc/ad7124.c | 86 ++++++++++++++- drivers/iio/adc/ad7192.c | 64 ++++++++++- drivers/iio/adc/ad_sigma_delta.c | 143 +++++++++++++++++++++++-- include/linux/iio/adc/ad_sigma_delta.h | 38 +++++++ 4 files changed, 315 insertions(+), 16 deletions(-) -- 2.25.1