On 10/27/21 2:54 AM, William Breathitt Gray wrote:
On Sat, Oct 16, 2021 at 08:33:41PM -0500, David Lechner wrote:
This documents new counterX/latch_mode* and
counterX/countY/latched_count* attributes.
The counterX/signalY/*_available are moved to the
counterX/countY/*_available section similar to the way we already have
The counterX/*_component_id and The counterX/signalY/*_component_id
grouped together so that we don't have to start a 3rd redundant section
for device-level *_available section.
@@ -147,6 +150,14 @@ Description:
updates the respective count. Quadrature encoding
determines the direction.
+What: /sys/bus/counter/devices/counterX/countY/latched_count
+KernelVersion: 5.16
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Latched count data of Count Y represented as a string. The value
+ is latched in based on the trigger selected by the
+ counterX/latch_mode attribute.
+
Latches are pretty common components of devices, and not simply limited
to latching the count data. I wonder if it would be better to omit the
"_count" suffix in order to make this more general. Well, the name
"latched_count" is suitable for counters so you probably don't need to
change it, but it's something to think about in the future.
I chose the name counterX/countY/latched_count since we already have
counterX/countY/count to read the same (not latched) count. This
indicates that they are the same quantity, just from a different
point in time.
Also for consideration, this particular hardware actually has 3
independent latched counts. One is triggered by the selected
latched_mode. One is triggered by the index signal and one is
triggered by the strobe signal.
The latter two are not implemented in this series, but if there were a
use for those, I would probably submit attributes index_latched_count
and strobe_latched_count. These are unaffected by the latch_mode.
Similarly, the unit timer has a timer latch and a period latch. If we
change the unit timer to be a Count as suggested, then the latched
timer would basically be the same as latched_count. Both of these
are triggered by the selected latch_mode.
So, I supposed if we wanted to keep things really generic, we would
want to introduce some sort of "latch trigger" component (synapse?).
There could theoretically be multiple configurable triggers, so
the proposed latch_mode might need to be made indexed or part of
an index component/extension.
What: /sys/bus/counter/devices/counterX/countY/name
KernelVersion: 5.2
Contact: linux-iio@xxxxxxxxxxxxxxx
@@ -209,6 +220,7 @@ What: /sys/bus/counter/devices/counterX/countY/count_mode_component_id
What: /sys/bus/counter/devices/counterX/countY/direction_component_id
What: /sys/bus/counter/devices/counterX/countY/enable_component_id
What: /sys/bus/counter/devices/counterX/countY/error_noise_component_id
+What: /sys/bus/counter/devices/counterX/countY/latched_count_component_id
What: /sys/bus/counter/devices/counterX/countY/prescaler_component_id
What: /sys/bus/counter/devices/counterX/countY/preset_component_id
What: /sys/bus/counter/devices/counterX/countY/preset_enable_component_id
@@ -218,6 +230,7 @@ What: /sys/bus/counter/devices/counterX/signalY/cable_fault_enable_component_id
What: /sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler_component_id
What: /sys/bus/counter/devices/counterX/signalY/index_polarity_component_id
What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_component_id
+What: /sys/bus/counter/devices/latch_mode_component_id
What: /sys/bus/counter/devices/unit_timer_enable_component_id
What: /sys/bus/counter/devices/unit_timer_period_component_id
What: /sys/bus/counter/devices/unit_timer_time_component_id
Just noticing here, I missed the counterX in the device-level components.
@@ -244,6 +257,22 @@ Description:
counter_event data structures. The number of elements will be
rounded-up to a power of 2.
+What: /sys/bus/counter/devices/counterX/latch_mode
+KernelVersion: 5.16
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Read/write attribute that selects the trigger for latching
+ values. Valid values are device-specific (given by
+ latch_mode_available attribute) and may include:
+
+ "Read count":
+ Reading the countY/count attribute latches values.
+
+ "Unit timeout":
+ Unit timer timeout event latches values.
+
+ The latched values can be read from latched_* attributes.
+
To make these modes more generic for use in future drivers, I suggest
removing the "Unit " prefix and just leaving that mode as "Timeout". In
a similar vein, rewording "Read count" to "Count read" would make this
mode easier to understand in case a future driver introduces a mode
called "Signal read" or similar.
Continuing my thoughts from above and taking this suggestion into
consideration...
Maybe we need a /sys/bus/counter/devices/counterX/latchY component.
This would represent the trigger for a latch. For the TI eQEP in this
series, there are potentially 3 of these (only one implemented for
now).
latchY would have a required `trigger` attribute that would describe
what triggers the latch. If the trigger is selectable, there would be
a `triggers_available` attribute that would list the possible triggers,
otherwise the `trigger` attribute would just be read-only. Available
triggers could could be "X read" where X is a fully qualified component
name, e.g. "Count0 count read" or a fully qualified event, e.g.
"Count1 overflow event" (this is unit timer timeout in generic counter
terms). But, there may be potential triggers that don't fit either
of these patterns.
Although not currently needed, the triggers for the index and strobe
latches on the eQEP get more interesting. The `triggers_available` for
the index latch are "index rising edge", "index falling edge" and
"software" (this would require a `software_trigger` attribute that
would be written to trigger the latch). The `triggers_available` for
the strobe latch are "strobe rising edge" and "strobe rising edge if
direction is clockwise and strobe falling edge if direction is
counterclockwise".
Circling back to the beginning, to read latched registers, there
would be attributes like counterX/countY/latchY_count instead of
the proposed counterX/countY/latched_count. So for the eQEP there
would be counter0/count0/latch0_count (triggered by reading
counter0/count0/count or counter0/count1 overflow event),
counter0/count0/latch1_count (triggered by index signal),
counter0/count0/latch2_count (triggered by strobe signal),
counter0/count1/latch0_count (unit timer latched timer trigger
by same trigger as counter0/count0/latch0_count) and
counter0/count0/latch0_ceiling (unit timer latched period
triggered by same trigger as counter0/count0/latch0_count).