[PATCH v1 1/2] iio: trigger: Replace explicit casting and wrong specifier with proper one

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



By unknown reason device name is set with an index casted from int
to unsigned long while at the same time with "%ld" specifier. Both parts
seems wrong to me, thus replace replace explicit casting and wrong specifier
with proper one, i.e. "%u".

Signed-off-by: Andy Shevchenko <andriy.shevchenko@xxxxxxxxxxxxxxx>
---
 drivers/iio/industrialio-trigger.c | 3 +--
 1 file changed, 1 insertion(+), 2 deletions(-)

diff --git a/drivers/iio/industrialio-trigger.c b/drivers/iio/industrialio-trigger.c
index 32ac1bec25e3..77fca24147b2 100644
--- a/drivers/iio/industrialio-trigger.c
+++ b/drivers/iio/industrialio-trigger.c
@@ -75,8 +75,7 @@ int __iio_trigger_register(struct iio_trigger *trig_info,
 		return trig_info->id;
 
 	/* Set the name used for the sysfs directory etc */
-	dev_set_name(&trig_info->dev, "trigger%ld",
-		     (unsigned long) trig_info->id);
+	dev_set_name(&trig_info->dev, "trigger%u", trig_info->id);
 
 	ret = device_add(&trig_info->dev);
 	if (ret)
-- 
2.30.2