Re: [PATCH 2/2] iio: sx9310: Add debouncer-depth parameters

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Mon, Mar 29, 2021 at 6:11 AM Stephen Boyd <swboyd@xxxxxxxxxxxx> wrote:
> Quoting Andy Shevchenko (2021-03-28 05:32:36)
> > On Sun, Mar 28, 2021 at 6:36 AM Gwendal Grignou <gwendal@xxxxxxxxxxxx> wrote:
> > >
> > > Semtech SX9310 SAR sensor has a debouncer filter: only when N
> > > measurements are above/below the far/close threshold an event is
> > > sent to the host.
> > > By default the debouncer is set to 2 events for the close to far
> > > transition and 1 event (no debounce) for far to close.
> > > It is a balance speed of detection and false positive avoidance.
> > >
> > > On some chromebooks, the debouncer is set to a larger number.
> > ...
> >
> > > +               ret = device_property_read_u32(dev, "semtech,close-debouncer-depth", &depth);
> > > +               ret = device_property_read_u32(dev, "semtech,far-debouncer-depth", &depth);
> >
> > Are they existing properties or new ones? To me sounds like the
> > latter. In such a case you missed DT bindings update.
>
> The bindings are part of patch #1.

Thanks, it means _I am_ missing them :-)

-- 
With Best Regards,
Andy Shevchenko



[Index of Archives]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Input]     [Linux Kernel]     [Linux SCSI]     [X.org]

  Powered by Linux