[PATCH 0/2] iio: sx9310: Add debouncer-depth parameters

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Semtech SX9310 SAR sensor has a debouncer filter: only when N
measurements are above/below the far/close threshold an event is
sent to the host.
By default the debouncer is set to 2 events for the close to far
transition and 1 event (no debounce) for far to close.
It is a balance speed of detection and false positive avoidance.

On some chromebooks, the debouncer is set to a larger number.

This patch applies on top of commit 103d6ec82676 ("iio: sx9310: Support ACPI properties")

Gwendal Grignou (2):
  dt-bindings: iio: sx9310: Add close/far debouncer strength
  iio: sx9310: Add debouncer-depth parameters

 .../iio/proximity/semtech,sx9310.yaml         | 18 ++++++++++++++++
 drivers/iio/proximity/sx9310.c                | 21 ++++++++++++++++++-
 2 files changed, 38 insertions(+), 1 deletion(-)

-- 