Semtech SX9310 SAR sensor has a debouncer filter: only when N measurements are above/below the far/close threshold an event is sent to the host. By default the debouncer is set to 2 events for the close to far transition and 1 event (no debounce) for far to close. It is a balance speed of detection and false positive avoidance. On some chromebooks, the debouncer is set to a larger number. This patch applies on top of commit 103d6ec82676 ("iio: sx9310: Support ACPI properties") Gwendal Grignou (2): dt-bindings: iio: sx9310: Add close/far debouncer strength iio: sx9310: Add debouncer-depth parameters .../iio/proximity/semtech,sx9310.yaml | 18 ++++++++++++++++ drivers/iio/proximity/sx9310.c | 21 ++++++++++++++++++- 2 files changed, 38 insertions(+), 1 deletion(-) -- 2.31.0.291.g576ba9dcdaf-goog