Re: [PATCH 25/29] dt-bindings:iio:temperature:melexis,mlx90632 conversion to yaml

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Thanks for the conversion. No idea which tag to put, so:
Acked-by: Crt Mori <cmo@xxxxxxxxxxx>

On Sun, 11 Oct 2020 at 19:10, Jonathan Cameron <jic23@xxxxxxxxxx> wrote:
>
> From: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx>
>
> Technically this could have gone in trivial-devices.yaml, but I have
> kept it as a separate binding due to the detailed additional description
> from the text file.
>
> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx>
> Cc: Crt Mori <cmo@xxxxxxxxxxx>
> ---
>  .../iio/temperature/melexis,mlx90632.yaml     | 55 +++++++++++++++++++
>  .../bindings/iio/temperature/mlx90632.txt     | 28 ----------
>  2 files changed, 55 insertions(+), 28 deletions(-)
>
> diff --git a/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml b/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml
> new file mode 100644
> index 000000000000..b547ddcd544a
> --- /dev/null
> +++ b/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml
> @@ -0,0 +1,55 @@
> +# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
> +%YAML 1.2
> +---
> +$id: http://devicetree.org/schemas/iio/temperature/melexis,mlx90632.yaml#
> +$schema: http://devicetree.org/meta-schemas/core.yaml#
> +
> +title: Melexis MLX90632 contactless Infra Red temperature sensor
> +
> +maintainers:
> +  - Crt Mori <cmo@xxxxxxxxxxx>
> +
> +description: |
> +  https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90632
> +
> +  There are various applications for the Infra Red contactless temperature
> +  sensor and MLX90632 is most suitable for consumer applications where
> +  measured object temperature is in range between -20 to 200 degrees
> +  Celsius with relative error of measurement below 1 degree Celsius in
> +  object temperature range for industrial applications. Since it can
> +  operate and measure ambient temperature in range of -20 to 85 degrees
> +  Celsius it is suitable also for outdoor use.
> +
> +  Be aware that electronics surrounding the sensor can increase ambient
> +  temperature. MLX90632 can be calibrated to reduce the housing effect via
> +  already existing EEPROM parameters.
> +
> +  Since measured object emissivity effects Infra Red energy emitted,
> +  emissivity should be set before requesting the object temperature.
> +
> +properties:
> +  compatible:
> +    const: melexis,mlx90632
> +
> +  reg:
> +    maxItems: 1
> +    description: Default is 0x3a, but can be reprogrammed.
> +
> +required:
> +  - compatible
> +  - reg
> +
> +additionalProperties: false
> +
> +examples:
> +  - |
> +    i2c {
> +        #address-cells = <1>;
> +        #size-cells = <0>;
> +
> +        temp-sensor@3a {
> +            compatible = "melexis,mlx90632";
> +            reg = <0x3a>;
> +        };
> +    };
> +...
> diff --git a/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt b/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt
> deleted file mode 100644
> index 0b05812001f8..000000000000
> --- a/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt
> +++ /dev/null
> @@ -1,28 +0,0 @@
> -* Melexis MLX90632 contactless Infra Red temperature sensor
> -
> -Link to datasheet: https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90632
> -
> -There are various applications for the Infra Red contactless temperature sensor
> -and MLX90632 is most suitable for consumer applications where measured object
> -temperature is in range between -20 to 200 degrees Celsius with relative error
> -of measurement below 1 degree Celsius in object temperature range for
> -industrial applications. Since it can operate and measure ambient temperature
> -in range of -20 to 85 degrees Celsius it is suitable also for outdoor use.
> -
> -Be aware that electronics surrounding the sensor can increase ambient
> -temperature. MLX90632 can be calibrated to reduce the housing effect via
> -already existing EEPROM parameters.
> -
> -Since measured object emissivity effects Infra Red energy emitted, emissivity
> -should be set before requesting the object temperature.
> -
> -Required properties:
> -  - compatible: should be "melexis,mlx90632"
> -  - reg: the I2C address of the sensor (default 0x3a)
> -
> -Example:
> -
> -mlx90632@3a {
> -       compatible = "melexis,mlx90632";
> -       reg = <0x3a>;
> -};
> --
> 2.28.0
>



[Index of Archives]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Input]     [Linux Kernel]     [Linux SCSI]     [X.org]