On Fri, 31 Jul 2020 09:01:14 +0200 Christian Eggers <ceggers@xxxxxxx> wrote: > Support for AMS AS73211 JENCOLOR(R) Digital XYZ Sensor. > > This driver has no built-in trigger. In order for making triggered > measurements, an external (software) trigger driver like > iio-trig-hrtimer or iio-trig-sysfs is required. > > The sensor supports single and continuous measurement modes. The latter > is not used by design as this would require tight timing synchronization > between hardware and driver without much benefit. > > Datasheet: https://ams.com/documents/20143/36005/AS73211_DS000556_3-01.pdf/a65474c0-b302-c2fd-e30a-c98df87616df > Signed-off-by: Christian Eggers <ceggers@xxxxxxx> A question inline about flipping to config mode mid capture. > --- > MAINTAINERS | 7 + > drivers/iio/light/Kconfig | 15 + > drivers/iio/light/Makefile | 1 + > drivers/iio/light/as73211.c | 780 ++++++++++++++++++++++++++++++++++++ > 4 files changed, 803 insertions(+) > create mode 100644 drivers/iio/light/as73211.c > ... > + > +static int as73211_write_raw(struct iio_dev *indio_dev, struct iio_chan_spec const *chan, > + int val, int val2, long mask) > +{ > + struct as73211_data *data = iio_priv(indio_dev); > + int ret; > + > + mutex_lock(&data->mutex); > + > + /* Need to switch to config mode ... */ Is this safe whilst we are doing a capture? You may want to claim_direct_mode for write_raw to ensure we don't get such a race. > + if ((data->osr & AS73211_OSR_DOS_MASK) != AS73211_OSR_DOS_CONFIG) { > + data->osr &= ~AS73211_OSR_DOS_MASK; > + data->osr |= AS73211_OSR_DOS_CONFIG; > + > + ret = i2c_smbus_write_byte_data(data->client, AS73211_REG_OSR, data->osr); > + if (ret < 0) > + goto error_release; > + } > + > + ret = _as73211_write_raw(indio_dev, chan, val, val2, mask); > + > +error_release: > + mutex_unlock(&data->mutex); > + return ret; > +}