Re: [PATCH] iio: humidity: hdc100x: fix IIO_HUMIDITYRELATIVE channel reporting

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Thu, Nov 21, 2019 at 12:39 PM Chris Lesiak <chris.lesiak@xxxxxxxxx> wrote:
>
> The IIO_HUMIDITYRELATIVE channel was being incorrectly reported back
> as percent when it should have been milli percent. This is via an
> incorrect scale value being returned to userspace.
>

 **sigh** another failure by me to follow the iio ABI.

Acked-by: Matt Ranostay <matt.ranostay@xxxxxxxxxxxx>

> Signed-off-by: Chris Lesiak <chris.lesiak@xxxxxxxxx>
> ---
>  drivers/iio/humidity/hdc100x.c | 2 +-
>  1 file changed, 1 insertion(+), 1 deletion(-)
>
> diff --git a/drivers/iio/humidity/hdc100x.c b/drivers/iio/humidity/hdc100x.c
> index 066e05f92081..ff6666ac5d68 100644
> --- a/drivers/iio/humidity/hdc100x.c
> +++ b/drivers/iio/humidity/hdc100x.c
> @@ -229,7 +229,7 @@ static int hdc100x_read_raw(struct iio_dev *indio_dev,
>                         *val2 = 65536;
>                         return IIO_VAL_FRACTIONAL;
>                 } else {
> -                       *val = 100;
> +                       *val = 100000;
>                         *val2 = 65536;
>                         return IIO_VAL_FRACTIONAL;
>                 }
> --
> 2.21.0
>