return value in hx711_reset() should indicate status of dout otherwise the calling function is reporting an error als false positive wait up to 1 second until the device is in normal state; by changing the channel on every trigger event it turned out that the former 100 ms are not enough for waiting until the device is in normal mode Signed-off-by: Andreas Klinger <ak@xxxxxxxxxxxxx> --- drivers/iio/adc/hx711.c | 13 ++++++------- 1 file changed, 6 insertions(+), 7 deletions(-) diff --git a/drivers/iio/adc/hx711.c b/drivers/iio/adc/hx711.c index d773fd69a76d..eabd2e66aca3 100644 --- a/drivers/iio/adc/hx711.c +++ b/drivers/iio/adc/hx711.c @@ -153,15 +153,16 @@ static int hx711_wait_for_ready(struct hx711_data *hx711_data) int i, val; /* - * a maximum reset cycle time of 56 ms was measured. - * we round it up to 100 ms + * in some rare cases the reset takes quite a long time + * especially when the channel is changed. + * Allow up to one second for it */ for (i = 0; i < 100; i++) { val = gpiod_get_value(hx711_data->gpiod_dout); if (!val) break; - /* sleep at least 1 ms */ - msleep(1); + /* sleep at least 10 ms */ + msleep(10); } if (val) return -EIO; @@ -203,9 +204,7 @@ static int hx711_reset(struct hx711_data *hx711_data) * after a dummy read we need to wait vor readiness * for not mixing gain pulses with the clock */ - ret = hx711_wait_for_ready(hx711_data); - if (ret) - return ret; + val = hx711_wait_for_ready(hx711_data); } return val; -- 2.1.4 -- -- To unsubscribe from this list: send the line "unsubscribe linux-iio" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html