On Sunday, November 19, 2017 5:15:03 PM CET Jonathan Cameron wrote: > On Sat, 28 Oct 2017 23:12:47 +0200 > > Stefan Brüns <stefan.bruens@xxxxxxxxxxxxxx> wrote: > > While the config uses the physical value corresponding to the LSB > > for both the power and the bus voltage register, the shunt voltage is > > specified as parts of 1 mV. Use the LSB physical value for all registers. > > > > No functional change. > > > > Signed-off-by: Stefan Brüns <stefan.bruens@xxxxxxxxxxxxxx> > > Applied Hi Maciej, I think you will have to rebase you calibration register patch on top of this series ... Kind regards, Stefan -- Stefan Brüns / Bergstraße 21 / 52062 Aachen home: +49 241 53809034 mobile: +49 151 50412019